Reset
Pin hole +Down
button
Abnormal error
Pin hole +
status
Down button
Overheat
/
protection
status
Collision detection
• The system is designed to avoid possible damages to equipment due to collision. When the desk detects a sudden change
in resistance, it will stop the movement and move in the reverse direction by approximately 30 mm-50 mm (depends on the
movement speed, collision force and the load during collision).
1 click the
/
pin-hole first,
then long
press down
button
Reset
/
operation
Rest for
/
approx. 18
minutes
before
continuing
operation of
unit
Orange
Steady
First, poke the pinhole at the bottom
light
on
of the hand controller with a pin
to enter the reset status (at this
time, the orange light will be steady
on), and then long press the down
button until the table goes down
to the lowest height, and then
raise it up 7 mm automatically to
complete the reset. After the reset is
successful, the orange light will turn
off.
Orange
Blinks
In the abnormal status, the orange
light
light continues to blink. Pressing any
button does not work. You need to
check if all the cables are properly
connected, and then perform the
reset.
Blue light
Steady
This is not an abnormal error status,
on
but due to the motor working
continuously, overheat protection
may activate. After approx. 18
minutes of rest, the blue light will
turn off and normal operation can
be resumed.