Descargar Imprimir esta página

Pro Spot SP-1 Manual De Instruccion página 14

Publicidad

Idiomas disponibles

Idiomas disponibles

Once a Synergic Curve is selected, Slope, BBT and Inductance settings go back to their default values.
PROG save & recall Key -
Use this Key to save and recall the points that the
operator can customize. Refer to paragraph 10.
MATERIAL Key -
6.2.1 Manual Mig/Mag (synergy OFF)
Regulation of the electronic inductance.
6.2.2 Synergic Mig/-------------Mag,
Pulsed Mig/Mag
Access to the screen for the synergic program adjustment.
Graphic Display -
MIG/MAG MODE:
PULSED, SYN ON, SYN OFF
Synergic Program Information
Wire Speed
Regulation Scale:
Manual-electronic inductance
SYN / PULSED- balance
Note: based on the set welding mode, some data on the MIG/MAG screen can not be visualized.
The Synergic Program indicates the effective working program inside the selected synergic curve (Gas,
Diameter, Material).
14
14
IND.: regulation of the electronic inductance value (0-11)
Low Value = more spatters
High Value = less spatters
POST GAS: Regulation of the gas outflow time at the end of welding (0 – 5 Sec.)
Hot Start: percentage of increase of welding current to make start easier (100 - 140%)
Duration of the Welding Current Slope Down (0,2 - 2s)
Hot Start Time
Hot Start: percentage of increase of welding current to make start easier (100 - 140%)
Percentage of reduction of the welding parameter during the crater Filler (30 - 100%)
Duration of the Welding Current Slope Down (0,2 - 2s)
-
4
-
6.2
Figure 14
-
2
SYNERGIC WORKING POINT
7.3
Figure 15
5
6.2
Digital Ammeter/Voltmeter
Synergic Working Point
Pointer:
Manual - voltage
SYN/PULSED - Thickness
Working Modes:
2Stroke
4Stroke
Spot
4
33

Publicidad

loading

Productos relacionados para Pro Spot SP-1