Operation
guidelines for
automobile
pipeline
inspection
Turn off the engine ignition switch.
NOTE
All leak detection of automobile piping systems must be
performed with the engine turned off.
Remove the intake air filter, while some models need to remove
the throttle valve.
Clean the inner wall of the test pipe and install the conical
adapter of the air inlet on the test pipe.
The smoke leak detector is powered by DC 12V car battery
only.
The cone on the smoke outlet pipe has air pressure output
when press the air mode switch.
Press the smoke control switch again, the indicator lights on,
wait for about 10 seconds, insert the cone head on the smoke
outlet pipe into the air inlet taper adapter when the smoke
becomes thick.
Wait for about 1 to 2 minutes, you can use a flashlight with
strong light to help find the leaks in the pipeline and diagnose
the leakage status.
After the test is completed, turn off all switches, recycle and
save the remaining test oil, put away all accessories, and
confirm that there is no omission.
NOTE
If only part of the system needs to be tested or if the system
being tested has other openings that need to be sealed, a plug
kit can be used, which can also be used to seal the intake
manifold.
WARNING
When the internal temperature reaches 75°C, the detector will
start self-protection function and stop working automatically.