Instruction of
smoke leak
detector
pressure
gauge
Airbag
adapter
instructions
The smoke leak detector pressure gauge has two main
●
functions, one is for machine self-test, and the other is for
pre-assessment of the pipeline system. If the pointer of the
pressure gauge keeps still, which represents there is a
relatively serious leak in the pipeline; if the pointer rises slowly,
which indicates that there is a leak in the system. In this case,
you can turn on the smoke switch to output smoke to locate the
leak.
Airbag adapters are suitable for non-circular connections. While
for round and oval ports, please use the inlet tapered adapter for
normal cases.
●
Before using the airbag adapter, be sure to clean the inner wall
of the intake manifold (or other test interfaces) to prevent sharp
protrusions from piercing the airbag adapter.
●
Put the air bag (Z) into the test port.
●
Press the hand pump (X) until the bladder (Z) inflates and fully
seals the test port.
Connect the cone head on the smoke outlet pipe with the
●
smoke guide pipe (Y), introduce gases and smoke into the duct
to be tested.
●
After the test is completed, turn the pressure relief valve (W)
counter clockwise, take out the car air inlet adapter from the
test port, clean and save it.
NOTE
Airbag adopter can not contact with corrosive oil.
W
X
7
Y
Z