Cleaning and Maintenance
Please clean the filter, external water pump filter tube, water tray, water tank, and other parts every 7
days.
Note: Please turn the device off a few minutes before washing. The external water pump can be
wiped but do not soak in water. The metal docking area between the external water pump and the
base must be kept dry.
Filter Replacement
1. The filter must be replaced every 30 days. The yellow light will flash if the filter lifespan is shorter than
3 days.
2. After replacing the filter, tap the external water pump key four times consecutively to reset the filter
lifespan. Once the reminder lights are off, the filter restarts its new round of 30-day countdown.
Follow the steps below to replace a new filter:
Step 1: Remove the filter and tear off the
heat shrinkage film on its surface. Then
soak the filter in water for 5 minutes.
3
1
2
Step 3: Install the new filter and place the
water tray and external water pump back
in that order.
Note: When the device is shut down, the countdown of filter's lifespan will still continue.
External Water
Pump Filter Tube
1
3
2
Step 2: Pick up the external water
pump and water tray, and remove
the old filter.
Typ
e-
c
Typ
e-
c
Step 4: Reset the filter lifespan on the
device or APP after the replacement
is complete.
5
Plug-in Mode
Indicator Light Instructions
External Water Pump Indicator Light
Indicator Status
Device Status
Blue Light Always On
Water dispensing & UV irradiation normal
Green Light Flashes
Battery is recharging
Green Light Always On
Battery is fully-recharged
Red Light Always On
Low battery
Filter lifespan ≤ 3 days
Yellow Light Flashes
to reset the filter countdown.
Base Indicator Light
Indicator Status
Device Status
White Light Flashes
The device is trying to connect to the network./The device goes offline.
White Light Always On
The device has finished network configuration.
Lights Off
Device off
Green Light Flashes
The weighing data has been reset to zero
Twice
(
)
APP Connection
1. Please scan the QR code to download and install the Pawaii APP.
2. The fountain automatically enters the network configuration setting once you
turn it on for the first time.
3. Ensure your mobile phone's Wi-Fi and Bluetooth are on, then open the
Pawaii APP. Click the "+" icon on the homepage to add your device, and bind the
device according to the instructions.
Note:
• Please power on the fountain in advance before conducting network configuration.
• You can only configure your device under the 2.4GHz Wi-Fi connection. Please confirm that your router
operates in the 2.4GHz band if you experience difficulties connecting.
• The water intake data will be reported in real-time under plug-in mode.
• The water intake data will be reported once every four hours under battery-operated mode.
• Manual Network Configuration:
It is best to do a manual configuration when switching networks. To do this, hold the network configura-
tion key/base indicator for 3 seconds and enter the system after a beep sound. Then click the "+" icon
on the homepage to add your device.
APP Function
• Drinking time, drinking duration, drinking intake; real-time monitoring and data update every 4 hours.
• Power on/off, manual dispensing, filter countdown reset, cleaning countdown reset; doable via the APP.
• Filter replacement reminder, water level reminder, power shortage reminder, and error reminder;
update in real-time.
Press the key at the top four times
(
)