OPERATION (Units Made Prior to July 2018)

Refrigerated cycle

Freezers: The evaporator fans will run at any time when the evaporator coil temperature is below 54° F (12°C). Fans will
also keep running when door is open but cycle off during a defrost period. The door switch will activate the lights when
opened.
1.
Every 8 hours, the unit will turn off and electric heater will turn on to defrost. The controller now displays the defrost
symbol. When the coil temperature reaches 41°F (5°C) or after 30 minutes of defrost, the unit will turn on again.
2.
Anti-condensation heaters on door frames work in conjunction with the compressor.
3.
Recommended holding temperature range: -10° to 10°F (-23° to 12°C).
4.
Comes factory set to 5°F (-15°C).

Power Switch:

The power switch is located on the front of the bottom panel. When the unit is on, the switch will glow green.

SOLID-STATE THERMOSTAT DESCRIPTIONS (Units Made Prior to July 2018)

1. FRONT PANEL COMMANDS

Press and release
• Scroll through menu items
• Increases values
Press for at least 5 seconds
• Activates the Manual Defrost function
Press and release
• Returns to the previous menu level
• Confirms parameter value
Press for at least 5 seconds
• Activates the Standby function (OFF)
(when outside the menus)

1.1 Function of LEDS

On
Flashing
On
Flashing
On
On
Flashing
Compressor enabled
a delay, a protection or a locked start-up
Defrost in progress
manual or Digital Input (D.I.) activation
Fans output enabled
alarm active
alarm acknowledged
ºF
AUX
SET
ºC
Press and release
• Scroll through menu items
• Decreases values
Press for at least 5 seconds
• Configurable function by user
set
Press and release
• Displays alarms (if active)
• Opens Machine Status menu
• Confirm commands
Press for at least 5 seconds
• Opens Programming menu