Descargar Imprimir esta página

Taurus IS10KT Manual De Instrucciones página 59

Publicidad

Idiomas disponibles

Idiomas disponibles

10.1 Error code
If there is any failure,the LCD screen will display an alarm message. In this case,the inverter
messages are listed Table 10.1.
Auxiliary switch power supply
F10
F13
F15
AC firmware over current
GFCI(RCD) Ac leakage
F16
AC over current fault of
F18
DC over current fault of the
F20
AC leakage current is transient
F23
DC insulation impedance
F24
F30
AC main contactor failure
F35
AC over current (one cycle)
F39
Grid voltage fault
failure
Reserved
current fault
hardware
hardware
over current
failure
No AC grid
1. Turn off DC/AC switch, and turn on DC/AC switch 10mins
later;
2. If the fault still exists, please contact us for help.
1. Loss of one phase or AC voltage detection part failure or relays
not closed;
2. Seek help from us, if can't go back to normal state.
1. Restart inverter and check whether it is in normal;
2. Seek help from us, if can't go back to normal state.
1. Check PV module connection;
2. Turn off the DC/AC switch and then wait 1~2 minute, then
turn on the DC/AC switch again;
3. Seek help from us, if can't go back to normal state.
1. Restart inverter and check whether it is in normal;
2. Seek help from us, if can't go back to normal state.
1. Check DC input power is within the allowed range;
2. Restart inverter and check whether it is in normal;
3. Seek help from us, if can't go back to normal state.
1. Please wait for a while and check whether it is normal;
2. If still same, and turn off the DC switch and AC switch and
wait for one minute and then turn on the DC/AC switch;
3. Seek help from us, if can't go back to normal state.
1. Check PV panels connection and restart inverter. This
problem is caused by the PV side usually;
2. If the fault still exists, please contact us for help.
1. Turn off the DC/AC switch and then wait 1~2 minutes, then
turn on the DC/AC switch again;
2. If the fault still exists, please contact us for help.
1. Check AC grid voltage;
2. Check whether the AC output connection is in good
condition;
3. If the fault still exists, please contact us for help.
1. Wait for inverter to return to normal;
2. Disconnect DC switch and AC switch, and reconnect DC
switch and AC switch 10min later to restart the inverter;
3. If the fault still exists, please contact us for help.
- 36 -

Publicidad

loading