ENGLISH
1. MC4 connection cables
2. Solar panel
Maximum power (Pmax)
Voltage at Pmax (Vmpp)
Current at Pmax (Impp)
Open-circuit voltage (Voc)
Short-circuit current (Isc)
Cell type
General instructions
Before using this appliance, read the operating instructions carefully.
Keep the manual for future use.
General assembly instructions
Note: as soon as the solar panel is exposed to light or sunlight, the terminals in the junction box are energised. To avoid
short circuits when mounting and connecting the solar panels, you can turn the panels away from the light or cover
them so that they do not produce electricity during the assembly process. Remove the cover when the connection is
complete.
Note: The solar panels positive and negative cables should be disconnected before installation.
1. Do not step, stand or jump on any part of the panel. Uneven pressure may damage the cells.
2. Never try to disassemble the panel.
3. Keep all electrical contacts clean and dry.
4. Avoid drilling or welding in the frame wherever possible.
5. Do not use sharp metal tools or other objects that may scratch the surface of the panel.
6. Do not carelessly bend, shake, fold or drop the panel.
7. Use insulated tools suitable for electrical installation.
8. Choose a location for the panel with as little shade as possible. Keep in mind that if the solar panel is shaded, the
power output will decrease.
9. Always connect the battery to the charge controller before connecting the solar module.
10. Check the system regularly to make sure it is functioning normally.
11. Photovoltaic systems must only be installed by qualified personnel.
Installation methods
1. The provided installation methods serve as guidelines. Mestic only provides certain installation accessories, but
does not supply components for a comprehensive vehicle system installation. System installers should verify that
the installation is safe and complies with all panel specifications.
2. The panel can be fastened through the holes in its edges, or by gluing with appropriate mounting UV and water
resistant sealant, glue or double-sided tape on the back of the panel.
3. A solar panel must be connected to a battery system via a charge controller. For correct installation, follow the
instructions supplied with the controller.
Technical specifications
MSFL-100
100 W
19.5 V
5.13 A
23.4 V
5.54 A
Monocrystalline PERC
1
2
MSFL-150
150 W
19.5 V
7.69 A
23.4 V
8.37 A
Monocrystalline PERC
MSFL-200
200 W
20 V
10.1 A
24 V
10.3 A
Monocrystalline PERC