OPERATING MANUAL
WARNINGS
BEFORE USING THE APPLIANCE READ THE HANDBOOK
WARNINGS
THE APPLIANCE MUST BE USED BY QUALIFIED PERSONNEL
WARNINGS
DO NOT OPEN THIS DEVICE FOR ANY REASON - PLEASE CONTACT THE FAZZINI S.R.L. TECHNICAL DIVISION FOR ANY PROBLEM SHOULD ARISE
CAUTIONS
DO NOT DIP THE APPLIANCE UNDER WATER
DO NOT LEAVE THE APPLIANCE EXPOSED TO ATMOSPHERIC AGENTS OR HEAT SOURCES
DO NOT LET CHILDREN OR INCAPABLE PERSONS USE THE APPLIANCE WITHOUT THE NECESSARY SUPERVISION.
BEFORE STARTING CLEAN THE DEVICE
DO NOT USE THE APPLIANCE FOR AIMS OTHER THAN THOSE FORESEEN BY THE MANUFACTURER. USING THE APPLIANCE UNDER DIFFERENT
CONDITIONS THAN THOSE SPECIFIED IN THIS HANDBOOK MAY PREJUDICE ITS SAFETY AND ITS TECHNICAL PARAMETERS
TECHNICAL DATA
MODEL
SIZE
LENGTH
WIDTH
HEIGHT
FAZZINI S.R.L. TAKES ALL THE NECESSARY MEASURES TO GUARANTEE THE SAFETY OF ITS PRODUCTS. HOWEVER IT IS IMPORTANT TO COMPLY
WITH BASIC SAFETY RULES.
ON FIRST USE, CHECK THAT THE APPLIANCE SHOWS NO BREAKS, CRACKS OR OPENINGS CAUSED BY TRANSPORTATION
OPERATING INSTRUCTIONS
THE APPLIANCE IS A PORTABLE ASPIRATOR FOR EMERGENCY USE, MINOR SURGERY AND AIMED AT FREEING THE AIRWAYS FROM ORGANIC
SECRETIONS.
OPERATIONAL TEMPERATURE: BETWEEN 0° AND 50°
OPERATIONAL HUMIDITY: BETWEEN 20 AND 90% RU
1.TIGHTLY SCREW THE LID ON THE JAR TO GUARANTEE A PERFECT SEAL
2.CONNECT THE SHORT TUBE TO FILTER 1 ON THE ''ASPIRATION'' 2 VENT
3.CONNECT THE OTHER END OF THE TUBE TO THE ''VACUUM'' 3 VENT WITH THE FLOAT ON THE JAR'S LID
4.CONNECT THE LONG TUBE 4 TO THE OTHER ''PATIENT'' 5 VENT ON THE JAR'S LID (VENT WITHOUT FLOAT)
5.CONNECT THE OTHER END OF THE LONG TUBE 4 THE PROBE CONNECTOR 6 AND EVENTUALLY THE SUPPLIED PROBE
6. PRESS THE PEDAL (7)
7.IT IS RECOMMENDED TO CARRY OUT A FIRST ASPIRATION CYCLE WITH AT LEAST 500 ML OF WATER ONLY.
8.THE ASPIRATED FLUID WILL FLOW IN THE RELEVANT JAR. SHOULD THE AMOUNT OF FLUID EXCEED THE JAR'S CAPACITY, THE OVERFLOW
VALVE WILL STOP ASPIRATION.
ACCESSORIES INCLUDED
CODE N°
05.0001
05.00552
05.0010
05.0016
SHOULD ACCESSORIES BE USED OTHER THAN THOSE SUPPLIED BY FAZZINI S.R.L., YOU MUST MAKE SURE THAT THEY HAVE THE SAME
CHARACTERISTICS AS THE ORIGINAL ONES.
NOTE: THE SUPPLIED JARS ARE NOT MEANT TO BE USED AS MEASURERS, AND PROVIDE ONLY AN INDICATION OF THE CONTAINED QUANTITY.
User Manual_F-170_Rev.5_16_09_2021
F-170
260 MM
180 MM
240 MM
DESCRIPTION
COMPLETE JAR 1000 ML
SET OF TUBES
ASPIRATION PROBE CH 14 (DISPOSABLE)
ANTIBACTERIAL/HYDROPHOBIC FILTER (DISPOSABLE)
Rev.5 del 16.09.2021
WEIGHT
MAX ASPIRATION
Istruzioni per l'uso
Instructions for use
F-170
Mode d'emploi
Manual de instrucciones
Instruções de uso
2.0 KG
-0,30 BAR (PEDAL)
Pag. 5