NOTICE D'EMPLOI
IMPORTANT
CONSULTER LA NOTICE AVANT D'UTILISER L'APPAREIL
IMPORTANT
L'APPAREIL NE DOIT ÊTRE UTILISÉ QUE PAR DU PERSONNEL QUALIFIÉ
IMPORTANT
NE JAMAIS OUVRIR L'APPAREIL: POUR TOUTE REPARATION, CONSULTER LE SERVICE TECHNIQUE DE LA SOCIETE FAZZINI S.R.L.
RECOMMANDATIONS
LORS DE L'UTILISATION DE L'APPAREIL, OBSERVER SCRUPULEUSEMENT LES PRECAUTIONS SUIVANTES:
NE JAMAIS LE PLONGER DANS L'EAU.
NE PAS LE LAISSER EXPOSÉ AUX AGENTS ATMOSPHÉRIQUES NI AUX SOURCES DE CHALEUR.
NE PAS PERMETTRE AUX ENFANTS OU AUX PERSONNES INAPTES D'Y TOUCHER.
AVANT DE NETTOYER L'APPAREIL,
NE PAS S'EN SERVIR POUR DES USAGES DIFFÉRENTS DE CEUX QUI ONT ÉTÉ PRÉVUS PAR LE FABRICANT.
L'UTILISATION DE L'APPAREIL DANS DES CONDITIONS DIFFÉRENTES DE CELLES QUI SONT INDIQUÉES DANS LA PRÉSENTE NOTICE RISQUE D'EN
COMPROMETTRE LA SÉCURITÉ ET LES PARAMÈTRES.
CARACTÉRISTIQUES TECHNIQUES
MODÈLE
DIMENSIONS:
LONGUEUR
LARGEUR
HAUTEUR
LA SOCIÉTÉ FAZZINI S.R.L. FAIT TOUT CE QU'IL FAUT POUR GARANTIR LA SÉCURITÉ DE SES ARTICLES:
IL EST CEPENDANT ESSENTIEL DE SE CONFORMER RIGOUREUSEMENT AUX RÈGLES DE SÉCURITÉ. TOUJOURS LORS DE LA PREMIÈRE UTILISATION;
VÉRIFIER QUE L'APPAREIL NE PRÉSENTE AUCUNE CASSURE, FÊLURE OU AUTRE DOMMAGE CAUSÉ PAR LE TRANSPORT. SI C'EST LE CAS, NE PAS
S'EN SERVIR.
INSTRUCTIONS POUR L'EMPLOI
L'APPAREIL EST UN ASPIRATEUR PORTATIF POUR EMERGENCE, CHIRURGIE MINEURE ET DESTINE A LIBERER LES VOIES RESPIRATOIRES DES
SECRETIONS ORGANIQUES.
TEMPÉRATURES DE SERVICE: COMPRISES ENTRE 0 ET 50°
HUMIDITÉ DE SERVICE COMPRISE ENTRE 20 ET 90% D' H.R.
1. VISSER FORTEMENT LE COUVERCLE SUR LE BOCAL POUR ASSURER UNE PARFAITE ETANCHÉITÉ.
2. RELIER LE TUYAU COURT AVEC FILTRE 1 AU RACCORD "ASPIRATION" 2
3. RELIER L'AUTRE EXTRÉMITÉ DU TUYAU AU RACCORD "VACUUM" 3 AVEC FLOTTEUR SUR LE COUVERCLE DU BOCAL
4. RELIER LE TUYAU LONG 4 A L'AUTRE RACCORD 5 "PATIENT" SUR LE COUVERCLE DU BOCAL (RACCORD SANS FLOTTEUR)
5. RELIER L'AUTRE EXTRÉMITÉ DU TUYAU LONG 4 AU RACCORD 6 POUR ENFILER LA SONDE ET, LE CAS ÉCHÉANT, LA SONDE EN DOTATION
6. POUSSEZ LE PEDAL (7)
7. IL EST CONSEILLÉ DE PROCÉDER À UN PREMIER CYCLE D'ASPIRATION AVEC AU MOINS 500 ML D'EAU PURE
8. LE LIQUIDE ASPIRÉ COULERA DANS LE BOCAL. SI LA QUANTITÉ DE CE LIQUIDE EST SUPÉRIEURE À LA CAPACITÉ DU BOCAL, LA VALVE DE TROP-
PLEIN ARRÊTE L'ASPIRATION.
CODE N°
05.0001
05.00552
05.0010
05.0016
SI L'ON UTILISE DES ACCESSOIRES AUTRES QUE CEUX FOURNIS PAR FAZZINI S.R.L., IL EST INDISPENSABLE DE S'ASSURER QUE LEURS
CARACTERISTIQUES SONT IDENTIQUES A CELLES DES ACCESSOIRES D'ORIGINE.
LES BOCAUX FOURNIS N'ONT PAS UNE FONCTION DE MESURE: ILS NE FOURNISSENT QU'UNE INDICATION DE LA QUANTITE QU'ILS
CONTIENNENT. CE QU'IL FAUT FAIRE APRÈS UTILISATION DE L'APPAREIL. ATTENTION: TOUJOURS SE SERVIR DES MOYENS DE PROTECTION
User Manual_F-170_Rev.5_16_09_2021
F-170
260 MM
180 MM
240 MM
Rev.5 del 16.09.2021
POIDS
ASPIRATION MAXIMALE
ACCESSOIRES EN DOTATION
DESCRIPTION
BOCAL COMPLET 1000 ML
SÉRIE DE TUYAUX
SONDE ASPIRATION CH 14 (JETABLE)
FILTRE ANTIBACTERIEN/HYDROFUGE (JETABLE)
Istruzioni per l'uso
Instructions for use
F-170
Mode d'emploi
Manual de instrucciones
Instruções de uso
2.0 KG
-0,30 BAR
Pag. 7