8
CLOCKED SEQUENTIAL CONTROL MODULE 1027
CLOCKED SEQUENTIAL CONTROL MODULE 1027 Controls
(2)
(4)
(5)
(6)
(7)
(8)
(9)
(10)
(11)
(12)
(13) (14)(15)(16)(17)
(1)
(3)
(18) (19)
(20)
(EN) Controls
CH A / CH B / CH C SEQUENCER
(1)
COLUMNS – Use the knobs to set the
control voltage output for each step. Each
column sends out control voltages via
that channel's respective CH A / CH B / CH
C output jack.
(2)
STEP LEDs – Each LED lights to indicate its
respective sequencer step is active.
POSITION GATES – Each of these
(3)
output jacks sends out a gate signal for
its respective sequence step via cables
with 3.5 mm TS connectors. These 8 gate
output signals are also available via the
12-pin GATE OUT LINK CONNECTOR located
on the module underside. This 12-pin
connector can connect to and trigger
other compatible modules, such as the
MIX-SEQUENCER MODULE 1050, via a
12-pin ribbon connector.
(4)
RATE – This knob controls the step speed
at which the sequencer moves from step
to step. The knob operates in two overall
frequency ranges determined by the
LOW/HIGH switch.
(5)
LOW/HIGH – Use this sliding switch
to set whether the RATE knob operates
in a lower-frequency (LOW) or higher-
frequency (HIGH) range.
(6)
% PULSE WIDTH – Select between width
settings for the rectangular waveform
ranging from 5% to 95% duty cycle. The
PULSE WIDTH control operates on the CLK
OUT jack only, making this control very
useful for triggering other modules such
as envelope generators, and so on.
Quick Start Guide
9
INT/EXT – Use this switch to select
(7)
between internal (INT) or external (EXT)
pulse width control voltage. When EXT is
selected, the % PULSE WIDTH control knob
is disabled.
(8)
ON /OFF – This button starts or stops the
sequence with a manual button push.
(9)
STEP – Press this button to manually
progress to the next sequencer step.
RESET – Press this button to manually
(10)
restart the sequence at step 1.
(11)
STEP – Use this jack to route external
trigger signals for the STEP button into
the module via cables with 3.5 mm TS
connectors.
(12)
RESET – Use this jack to route external
trigger signals for the RESET button
into the module via cables with 3.5 mm
TS connectors.
(13)
ON – Use this jack to route external
trigger signals to enable the step counter
into the module via cables with 3.5 mm
TS connectors.
OFF – Use this jack to route external
(14)
trigger signals to disable the step counter
into the module via cables with 3.5 mm
TS connectors.
RATE – Use this jack to route in external
(15)
control voltage signals for the sequencer's
step speed (usually controlled by the
RATE knob) via cables with 3.5 mm
TS connectors.