Operating Instructions
Safety Switch TP...AS2
Status table
Programming
Guard closed, guard locking active or not active
Intermediate state during opening or closing of the guard.
Dual‑channel
dependent
Intermediate state during opening or closing of the guard.
Synchronization time 3 s
Guard closed and locked
Guard closed and not
State
Switch S1 (internal) open
Switch S2 (internal) open
Guard open
Address 0 or communication disrupted
Guard open
locked
v
h
D0, D1
D2, D3
Code sequence
Half-se-
00
quence
Half-se-
00
quence
00
00
–
9
Monitor diagnostics
Green
On opening: yellow flashing
On closing: red
After completion of the synchronization time: yellow flashing
Yellow flashing if guard was previously closed.
Red if guard was previously open.
Red
Gray