D D i i m m e e n n s s i i o o n n s s
D D i i m m e e n n s s i i o o n n s s
W W a a t t t t a a g g e e
" " A A " " ( ( L L e e n n g g t t h h ) )
500
28" (709mm)
750
36" (912mm)
1000
48" (1216mm)
1250
60" (1520mm)
1500
72" (1824mm)
2000
96" (2432mm)
2500
120" (3040mm)
5" (127mm)
K.O.
2"
(51mm)
Fig. 1
Protector
To other
heater
GND.
Power Supply
Fig. 2 Wiring Diagram
O O P P E E R R A A T T I I O O N N I I N N S S T T R R U U C C T T I I O O N N S S
1. This heater must be properly installed before it is used.
2. Heater must be controlled by a thermostat. If thermostat is
internal factory installed see below. If external thermostat is
provided, refer to the installation and operating instructions
provided with thermostat.
3. When factory thermostat is provided, the control will be locat-
ed inside heater behind grille with access to the thermostat
shaft obtained through the grille louver opening using a small
flat blade screwdriver.
4. On initial start up and check out, before heater is energized,
rotate thermostat shaft to the full counter-clockwise (lowest
heat) setting. Connect power to the heater and check to ver-
ify the heater is not heating. If heating, disconnect and
check wiring.
" " N N " "
" " B B " "
H H o o l l e e s s
–
–
–
–
19" (481mm)
2
16.68" (423mm)
4
20.63" (523mm)
4
21.5" (545mm)
6
27.5" (697mm)
6
A
B
5-13/16"
"N" mounting
(147mm)
holes
2" (51mm)
7/8" (21mm) x 1-1/8" (27mm) Nested KOs (Qty. 6)
Bottom View
Wall
Element
GND.
5" (127mm)
10"
(253mm)
K.O.
K.O.
1.32"
1.32"
(33mm)
3.25"
(82mm)
(33.4mm)
To other
heater
Factory wiring
Field wiring
5. Rotate thermostat shaft to the full clockwise (CW) (max heat)
setting and allow heater to operate for at least 5 minutes and
verify it is heating.
6. Allow heater to operate until room ambient reached desired
comfort level and then slowly rotate thermostat shaft counter-
clockwise (CCW) until you hear or feel a click. This will pro-
vide a set point to allow the thermostat to cycle the heater on
and off to maintain this approximate temperature. Some
slight adjustments may be necessary to fine tune the heater
to provide the most desired room comfort. To increase time
heater stays on and increase the room temperature, slightly
rotate the thermostat in the CW direction. Likewise, to
reduce the room temperature, slightly rotate the thermostat
in the CCW direction.
3
2.1"
(53mm)
For supply connections use 75°
copper wire as follows:
Amps
Wire size
12
14 AWG
16
12 AWG
24
10 AWG
35
8 AWG
45
4 AWG