STORAGE AND MAINTENANCE
Storage
14 Wide Pulse Injection Test
●
Press the up or down key to select "Item 14 Wide Pulse Injec-
tion Test".
Other steps are the same as in item 13.
●
15 Continuous Injection Test
●
Press the up or down key to select "Item 15 Continuous Injec-
tion Test".
●
Press function setting key to set working time. (Recommended
working time is less than 30s)
●
Other steps are the same as in item 02.
●
Turn off the power and unplug the power plug.
●
Put all connectors back into the accessory box for storage.
●
Drain the ultrasonic cleaning agent. Wipe the equipment clean
with a dry soft cloth.
●
If the machine needs to be stored for a long time, discharge the
testing agent into a bottle and seal it.
●
Replacement of Test Agent
When the test agent is used for a period of time, a lot of impuri-
ties will accumulate, and the agent containing dirt cannot be
used, otherwise it will easily block the fuel injector. When
replacing the agent, first open the testing agent drain valve to
empty the tank, and then inject a little testing agent to clean the
interior of the tank. After cleaning, drain the fuel tank again and
then pour 1L of new testing agent into the tank.
●
Fuse Replacement
There is a square box marked with a fuse on the power socket
on the left side of the device, and the fuse can be seen by
opening the box. If it is blown, replace it with a new one.
13