Installation
IMPORTANT: Pools with Variable Speed Pumps - The cleaner requires a minimum & maximum
rate of flow to operate optimally. If the variable speed pump has multiple speeds programmed,
use the Flow Gauge to calibrate the recommended flow rate at the pump's highest programmed
speed. This can be done by the using the Flow Regulator Valve and adjusting pump speed
manually to attain the correct flow at the highest preset speed. See page 5 for more information.
By using the highest preset speed, you'll ensure that all other settings will never exceed the
recommended maximum flow rate.
IMPORTANT: Pools with Heating - Heating must be turned OFF whenever the TracVac™ is in
use. If using Solar Heating and the TracVac™, always alternate schedules.
Pool Preparation
22
Use only hayward
Manually remove very large and excessive debris
from pool (ie. post- storm, spring cleaning/pool
opening situations).
Perform a backwash or clean filter cartidges, clean
your filter, skimmer baskets and pump basket.
Check that chemical balance is correct. If not, take
the time to correct it before using the TracVac™. If
you chemically shock the pool, wait 1-2 days before
continuing.
Point all your return fittings downward to maximize
cleaner pool coverage.
genuine replacement parts
®
EN
IMPORTANT: Turn OFF Pool Pump before you begin the next steps.
IMPORTANT: Ensure that your dedicated suction port is fitted with a Safety Vac-
Lock fitting (not included). If not, obtain one from your local pool store and have
it installed first.
Dedicated Suction
Port Connection
1. With the pump turned off, insert the
adjustable Flow Regulator Valve with the
Regulator Cap into the skimmer. Use the
Hose Cone Adapter to make a proper seal,
if necessary.
Safety Vac-Lock
Dedicated
Suction Port
1st Section of
Connector Hose
Use only hayward
genuine replacement parts
®
Skimmer
Regulator Cap
Flow
Regulator
Knob
Flow
Regulator
Valve
Hose Cone
Adapter
2. Install one section of hose into the Safety
Vac-Lock fitting of your dedicated suc-
tion port, as shown. If your pool does
not have a dedicated suction port, go to
Skimmer Only Connection.