Using a brush suitable for the purpose, wipe
the solution on all surfaces protruding above the
solution-level and on the underside of the top
cover(s).
4
Install the top cover(s) and operate the unit.
Allow the solution to agitate for about two
minutes. Drain the solution out of the bowl(s).
5
Use fresh product to chase any remaining
sanitizer from the bowl(s). Drain this solution. Do
not rinse out the machine.

6 ROUTINE MAINTENANCE

Daily: inspect the machine for signs of product
leaks past seals and gaskets. If proper assembly
does not stop leaks around seals or gaskets,
check for improper lubrication, worn or damaged
parts. Replace parts as needed with original
spare parts from the supplier.
6. 1 MAINTENANCE (TO BE
CARRIED OUT BY QUALIFIED
SERVICE PERSONNEL ONLY)
Montly: clean all internal components, primarily
the condenser, using compressed air.
To clean these internal parts, unplug the unit or
switch off the 2-pole wall breaker, then remove
front panel (dispensing side).
Condenser fins are very sharp. Use extreme
caution when cleaning.