Descargar Imprimir esta página

Sears Galaxy 721.36078 Manual De Uso Y Cuidado página 19

Publicidad

Idiomas disponibles

Idiomas disponibles

WARNING
Electric Shock or Personal
Injury
Hazard
Disconnect
electrical
supply before
servicing
or cleaning
the unit.
Failure to do so could result in
electric shock or personal
injury
from cleaner suddenly
starting.
Disconnect the power cord from the electrical
outlet.
To access the light bulb, first lower handle to
lay vacuum body flat and remove dust cover,
then remove the screws which secure the
light cover to the vacuum. Remove the cover.
Remove the light bulb by pushing the bulb in
while turning counterclockwise to release from
the slot. Pull the light bulb straight out.
To release
%ulb
Socket
Bulb
CAUTION
Do not use a bulb rated over 130 V
AC-25W.
During extended
use, heat
from the bulb could overheat
surrounding
plastic parts.
To replace
To replace the light bulb, carefully insert and
turn clockwise to fit securely into slot.
NOTE: Use Sears replacement bulb.
See page 4.
Position the light cover back on the vacuum.
Replace the light cover screws.
CAUTION
Do not plug in or turn on until
completely
reassembled.
-19-

Publicidad

loading