Troubleshooting T ips.
doesnotstart
Possible Causes
What To Do
The air conditioner
*Make sure the air conditioner plug is pushed
is unplugged,
completely
into the outlet,
The fuse is blown/circuit
*Check the house fuse/circuit
breaker box and replace
breaker is tripped,
the fuse or reset the breaker,
Power failure,
*The unit will automatically
restart in the settings last
used after the power is restored,
*There is a protective
time delay (approximately
3 minutes) to prevent tripping
of the compressor
overload,
For this reason, the unit may not start
normal cooling for 3 minutes after it is turned
back on,
The current
interrupter
*Press the RESET button located on the power cord plug,
device is tripped,
. If the RESET button will not stay engaged, discontinue
use of the air conditioner
and contact
a qualified
service technician,
Air conditioner does
Airflow is restricted,
. Make sure there are no curtains, blinds or furniture
not cool as it should
blocking the front of the air conditioner,
The temp control may
. In the C001mode, press the DecreaseT pad,
not be set correctly,
The air filter is dirty,
*Clean the filter at least every 30 days,
See the Care and Cleaning section,
The room may have been hot,
*When the air conditioner
is first turned on, you need
to allow time for the room to cool down,
Cold air is escaping,
*Check for open furnace registers and cold air returns,
Cooling coils have iced up,
*See "Air conditioner freezing up" below,
Air conditioner
Ice blocks the oir flow
oSet the controls at High Fanor High C001 and set the
freezingup
and stops the air conditioner
thermostat
to a higher temperature,
from cooling the room,
The rernomcontrol
The batteries are inserted
*Check the position of the batteries, They should be
is not working
incorrectly,
inserted in the opposite (+) and (-) direction,
The batteries may be dead,
. Replace the batteries,
Water drips outside
Hot, humid weather,
*This is normal,
Water dr us indoors
The air conditioner
is not
*For proper water disposal, make sure the air conditioner
tilted to the outside,
slants slightly from the case front to the rear,
Water collects n
basepan
Moisture removed from air
and drains into base pan,
*This is normal for a short period in areas with little
humidity; normal for a longer period in very humid areas,
Normal Operating Sounds
You may hear a pinging noise caused by
water being picked up and thrown against the
condenser on rainy days or when the humidity
is high, This design feature helps remove
moisture and improve efficiency,
You may hear the thermostat
click when the
compressor cycles on and off,
iiiiiiiiiiii_i_
Water will collect in the base pan during
high humidity or on rainy days, The water
may overflow and drip from the outdoor side
of the unit,
The fan may run even when the compressor
does not,