LED color
Continuously white
LED is off
6
Ambient conditions
EMC Limit Class A (electromagnetic immunity for industrial areas)
Only for use indoors
Recommendation: ESD workstation on installation
Feature
Ambient temperature
Storage temperature
Humidity
Protection Class
DIN EN 60529
7
Troubleshooting
Problem
Accessory does not work
Application is not
loaded
8
Cleaning instructions
 Do not use acidic cleaners or acetone. These can dissolve the plastic.
 Remove suspension bail.
8
Explanation
Software update is running.
Accessory is ready after the application has loaded.
 Press the Start button halfway to activate the tool light.
Data
0 °C ... 45 °C
-25 °C ... 70 °C
10% ... 90%, non-condensing
IP40
Possible cause
Accessory not activated by software
Accessory not properly installed
Accessory defective
Tool defective
Wrong software on TIM
Wrong software on STMD-H
TIM defective
Measurement card software is not
recognized
No application on the tool
CAN bus communication not
possible
P2408MA | 2019-06
Measure
 See Troubleshooting
 Check installation
 Replace accessory
 Replace tool
 Perform software update with
correct software
 Perform software update with
correct software
 Send tool for repair
 Use correct measurement card
software
 Perform software update with
correct software
 Make sure the tool is installed
correctly
 Make sure the correct TIM soft-
ware is used