Sounder Strobe Status
Status
Sound
Power on initialisation
Double chirp
(no fault)
Single chirp
 
EU Declaration of Conformity
Hereby,
Honeywell Products and Solutions Sàrl declares
equipment type
WSF-RR-RF / WSF-WR-RF
The full text of the EU DoC is available at the following internet address:
https://www.systemsensoreurope.com/products/category/wireless-fire-systems/
No. 
8
(3)
10 
11 
12 
13
(1)
14
(1)
15
(1)
16
(1)
17
(1)
18
(1)
19
(1)
20 
21
(1)
22 
23 
24
(1)
25 
26 
27 
28 
29 
30 
31 
32 
33
(2)
34 
35 
36
(1,2)
37
(1,2)
38
(1,2)
Notes:
(1) Tones not affected by intermittent user pattern
(2) Only available through Advanced Protocol commands
(3) Default tone; (Default volume = HIGH)
D200-311-00
Honeywell Building Technologies, Building 5 Carlton Park, King Edward Avenue, Narborough, Leicester LE19 3EQ
Meaning
Device is un-commissioned
(factory default)
Device is commissioned
that the radio
is in compliance
with directive
2014/53/EU
Pattern 
Nominal 
Frequency (Hz) 
Alternating 
554/440 
Alternating 
800/970 
Alternating 
800/970 
Alternating 
2400/2900 
Alternating 
2500/3100 
Alternating 
988/645 
Continuous 
660 
 
Continuous 
970 
Continuous 
1200 
Continuous 
2850 
Sweep 
150‐1000  
Intermittent 
660 
 
Sweep 
500 ‐ 1200  
 
Intermittent 
660 
 
Intermittent 
970 
 
Intermittent 
970 
 
Intermittent 
2850 
 
Intermittent 
970 
 
Intermittent 
950 
Continuous 
800 
 
Sweep 
400‐1200 
Sweep 
1200 ‐ 500  
Sweep 
2400 ‐ 2850  
 
Sweep 
500 ‐ 1200  
Sweep 
800 ‐ 970  
Sweep 
800 ‐ 970  
Sweep 
800 ‐ 970  
Sweep 
2400 – 2850  
Sweep 
500 – 1000  
Sweep 
500 – 1200 – 500  
Sweep 
800 – 1000  
Sweep 
2400 ‐ 2850  
 
Continuous 
4000 
Continuous 
440 
Continuous 
554 
 
Intermittent 
660 
 
Intermittent 
660 
 
Intermittent 
2850 
RF mesh network is created by the gateway. (For further information, see
the Radio Programming and Commissioning Manual - ref. D200-306-00.)
NOTE: Do not try to commission more than one gateway system at a
time in an area.
TESTING
Regular testing of fire alarm equipment is important to ensure its continued
correct operation. This device is designed to have a battery life of at least
4 years. The battery lifetime includes provision for periodical testing of the
sounder-strobe, providing this does not last for more than 30 seconds per
week.
Table 1: Sounder Tones
Switching Cycle 
2Hz (0.1s/0.4s) 
Rising from 150Hz to 1000Hz (10s), 40s 
@ 1000 Hz, falling from 1000Hz to 150Hz 
(10s), 20s @ 150Hz (Total 80s) 
0.5Hz 6.5s on, 13s off 
0.25s off, 3.75s on 
3.33Hz 0.15s on, 0.15s off 
0.8Hz 0.25s on, 1s off 
0.5Hz 1s on, 1s off 
1Hz (0.5s on, 0.5s off) 
0.22Hz (0.5s on, 0.5s off) rpt x3, 1.5s off 
(0.5s on, 0.5s off) rpt x3, 1.5s off 
0.99Hz 1s on, 0.01s off  
(0.5s off, 3.5s on)  
0.166Hz rise 1s, stable 4s, fall 1s  
0.05Hz 6.5s on, 13s off 
0.277Hz 1.8s on, 1.8s off 
4Hz (0.15s on, 0.1s off) 
Sounder output approved to EN 54-3
only at high volume setting. Output
sound pattern data, in accordance with
EN 54-3, is available in Document Ref:
S00-7001-xxx.
2nd Stage 
Tone 
1Hz 
2Hz 
3Hz 
2Hz 
2Hz 
  
  
  
  
1Hz 
 
7Hz  
50Hz  
7Hz  
1Hz  
50Hz  
7Hz  
2Hz  
1Hz  
 
 
 
10 
10 
22 
12 
10 
12 
22 
12 
20 
10 
10 
10 
35 
34 
10 
Patents Pending
I56-6661-001