• Make sure that there is adequate ventilation in the room where the appliance is to be installed.
• Do not install the appliance in rooms containing collective ventilation ducts, hoods with or without extractor, type B gas
appliances, heat pumps, or other appliances that, operating at the same time, can put the room in depression (ref. UNI 10683
standard)
• Make sure that the flue and the pipes to which the appliance will be connected are suitable for its operation. It is NOT allowed
the connection of various appliances to the same chimney.
• The diameter of the opening for connection to the chimney must at least correspond to the diameter of the flue gas pipe. The
opening must be equipped with a wall connection for the insertion of the exhaust pipe and a rosette.
• Always leave the recommended air pocket between the appliance and the walls, rear and side min. (see MARKING INFORMATION).
• Establish the type of ventilation (natural or forced) see chapter VENTILATION HOOD OR ADJACENT LOCAL.
• By means of the adjustable feet and using a level make sure that the device is perfectly levelled to allow a correct sliding of the door.
After testing the proper working of the appliance, some days from the installation, it is possible to proceed with the construction of
its aesthetic covering.
WARNINg - During the surround building operations it must kept in mind possible and subsequent electrical installed parts maintenance
(Fans, temperature probe, etc) and with hydraulic systems all parts connected to the product.
WARNINg - WHEN INsTALLINg INsERTs, ACCEss MUsT BE PREVENTED TO THE INTERNAL PARTs OF THE APPLIANCE
AND IT MUsT NOT BE POssIBLE TO ACCEss LIVE PARTs DURINg ExTRACTION OPERATIONs. ANY WIRINg, FOR ExAMPLE
THE POWER CABLE OR ROOM PROBE, MUsT BE POsITIONED sO As NOT TO BE DAMAgED DURINg MOVEMENT OF THE
INsERT AND MUsT NOT COME INTO CONTACT WITH HOT PARTs.
La NORDICA S.p.A. declines all responsibility for damage to things and/or persons caused by the system. In
addition, it is not responsible for any product modified without authorisation and even less for the use of non
original spare parts.
Your regular local chimney sweep must be informed about the installation of the appliance so that he can check the correct connection
to the chimney.
FIRE-FIgHTINg sAFETY MEAsUREs
When installing the appliance, the following safety measures must be observed:
a)
In order to ensure sufficient thermal insulation, respect the minimum safety distance from objects or furnishing components
flammable and sensitive to heat and from materials with flammable structure (see DECLARATION OF PERFORMANCE -
All the minimum safety distances are shown on the product data plate and lower values must not be used.
b)
in front of the furnace door, in the radiation area, there must be no flammable or heat-sensitive objects or material at a distance of less
Picture 7
- A.. . This distance can be reduced to 40 cm where a rear-ventilated, heat-resistant protection device is installed in
than ...
front of the whole component to protect;
c)
If the product is installed on a no totally refractory floor, one must foresee a fireproof background. The floors made of inflammable
material, such as moquette, parquet or cork etc., must be covered by a layer of no-inflammable material (size according to regional
Picture
1).
law, see
The ash drawer must always be inserted when the appliance is in operation.
The solid combustion residues (ashes) must be collected in a metal container that is hermetically sealed and fire resistant. The appliance must
never be lit in the presence of gaseous emissions or vapours (for example: glue for linoleum, petrol, etc,). Do not place flammable materials in
the vicinity of the appliance.
During the combustion, thermal air is emitted by involving the heating of areas, door and glass hearth, of the door handles or
controls, of the smokes pipe and, in case, of the front part of appliance. Avoid to touch those parts without a protective clothing
or without accessory tools (gloves resistant to heat, control devices). Ensure children are aware of these dangers and keep
them away from the furnace when it is on.Warn children that the device becomes very hot and that it must not be touched.
When using the wrong fuel or one which is too damp, due to deposits present in the flue, a flue fire is possible.
FIRsT-AID MEAsUREs
Should any fire arise in the stack or in the flue:
a)
Close the feeding door.
b) Close the registers of combustion air
c)
Extinguish the fire using carbon dioxide fire-fighting means (CO
d) Seek immediate intervention of FIRE BRIGADE.
DO NOT ExTINgUIsH FIRE UsINg WATER JETs. When the flue does not burn any more please arrange an examination by a specialist in order
to find possible cracks and permeable points.
BEAM PROTECTIONs
Considering the irradiation of the hearth, it is necessary to be particularly careful in protecting the beams while designing your stack. Consider
the proximity of beams to the external surfaces of the hearth, on one side, and the irradiation of the glass door, usually very close to the beams,