Descargar Imprimir esta página

JBM 50942 Manual De Instrucciones página 8

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 1
5.4. DC CURRENT
RANGE
RESOLUTION
20µA
10nA
200µA
100nA
2000µA
1µA
20mA
10µA
200mA
100µA
2A
1mA
20A
10mA
Overload Protection:
mA: F0.5A/250V fuse
20A: unfused
Voltage Drop: 200mV
5.6. TRANSISTOR HFE TEST
RANGE
HFE
PNP & NPN
0~1000
5.7. RESISTANCE
RANGE
RESOLUTION
200Ω
0.1Ω
2KΩ
20KΩ
10Ω
200KΩ
100Ω
2MΩ
1KΩ
20MΩ
10KΩ
200MΩ
100KΩ
Open Circuit Voltage: about 0.5V (200MΩ range is 3V)
Overload Protection: 250V DC/AC rms
5.10. FREQUENCY
RANGE
RESOLUTION
2KHz
1Hz
20KHz
10Hz
Over-load protect: 250V DC/AC rms
5.11. LOGIC
RANGE
VOLTAGE
≤1.8V
LOGIC
>1.8V & <2.4V
≥2.4V
6. OPERATION INSTRUCTION
6.1. MEASURING VOLTAGE
1) Connect the BLACK test lead to the "COM" jack and the RED to the "VΩ" jack.
2) Set the function switch to desired V
3) If the voltage magnitude to be measured is unknown beforehand, select the highest range.
4) Connect the test leads across the source or load to be measured.
5) Read LCD display. The polarity of the RED lead connection will be indicated when making a DC measurement.
Note:
a. In small range, the meter may display an unstable reading when the test leads have not been connected to the load to be measu-
red. It is normal and will not affect the measurements.
b. When the meter shows the over range symbol "1", a higher range must to be selected.
c. To avoid damage to the meter, don't measure a voltage which exceeds 1000Vdc (for DC voltage measurement) or 750Vac (for AC
voltage measurement).
ACCURACY
±(1.8% of rdg + 2 dgts)
±(2.0% of rdg + 2 dgts)
±(2.0% of rdg + 10 dgts)
TEST CURRENT
Ib≈10µA
ACCURACY
±(1.0% of rdg + 10 dgts)
±(1.0% of rdg + 4 dgts)
±(1.0% of rdg + 10 dgts)
±[5%*(rdg-10) + 10 dgts)
ACCURACY
±(3% of rdg + 5 dgts)
REMARK
▼and beep
▲ and ▼will both display or blank
or V
range.
5.5 AC CURRENT
RANGE
RESOLUTION
20µA
10nA
200µA
100A
2mA
1µA
20mA
10µA
200mA
100µA
2A
1mA
20A
10mA
Overload Protection:
mA: F0.5A/250V fuse
20A: unfused
Voltage Drop: 200mV
Frequency Range: 40Hz ~ 400Hz
Response: Average, calibrated in rms of sine wave
TEST VOLTAGE
Vce≈2.8V
5.8. DIODE AND CONTINUITY
RANGE
INTRODUCTION
The approximate forward volta-
ge drop will be displayed
The built-in buzzer will sound
if the resistance is less than
about 30±20Ω.
Overload Protection: 250V DC/AC rms
5.9. CAPACITANCE
RANGE
RESOLUTION
2nF
1pF
20nF
10pF
200nF
100pF
2uF
1nF
20uF
10nF
200uF
100nF
Overload Protection: F0.5A/250V fuse
Overload Protection: 250V DC/AC rms
· 8 ·
ACCURACY
±(2.0% of rdg + 5 dgts)
±(2.0% of rdg + 3 dgts)
±(2.0% of rdg + 5 dgts)
±(2.5% of rdg + 10 dgts)
REMARK
Open circuit
voltage: about
2.8V
Open circuit
voltage: about
2.8V
ACCURACY
±(4% of rdg + 5 dgts)

Publicidad

loading