Descargar Imprimir esta página

Anhang; Annex; Annexe; Anexo - Eneo VCQ-6057 Instrucciones De Manejo

Publicidad

Anhang / Annex / Annexe / Anexo
BYTE 1: Status code for normal operation modes
b7
b6
LOCK
VCR
BYTE 2: Status code for alarm operations: The first 4 bits show the sensor activated alarm status of each channel; next 4 bits show the video loss alarm
status of each channel. The digit „1" means alarm event is detected, and „0" means no alarm event is detected,
b7 - b4: Sensor Activated Alarm
b7
b6
CH4
CH3
Sensor activated Alarm
0001 = CH1 activated
0010 = CH2 activated
0100 = CH3 activated
1000 = CH4 activated
b5
b4
SEQU
QUAD
Auto-sequencing mode
0 = Auto sequencing mode
1 = Quad or full screen mode
VCR mode
0 = VCR operation
1 = Live operation
Security Lock mode
0 = Security lock ON mode
1 = Security lock OFF mode
Menu Setup mode
00 = Menu setup mode
b3 - b0: Video Loss Alarm
b5
b4
CH2
CH1
35
b3
b2
CH4
CH3
Display Mode
0 = Quad screen display
1 = Full screen display
b3
b2
CH4
CH3
Video Loss Alarm
0001 = CH1 activated
0010 = CH2 activated
0100 = CH3 activated
1000 = CH4 activated
b1
b0
CH2
CH1
Channel Select
1110 = CH1
1101 = CH2
1011 = CH3
0111 = CH4
b1
b0
CH2
CH1

Publicidad

Capítulos

loading

Este manual también es adecuado para:

Vbq-6045