OPERATING

GB
CONNECTING THE CONTROL PANEL TO THE SOCKET
HRC 1002 - HRC 1004

Connecting the instrument

After installing the socket as described above, proceed as follows:
• Remove the protective cover from the socket.
• Insert the instrument plug in the socket, taking care that the position of insertion is correct.
• Rotate the plug locking ring-nut clockwise (bayonet connection) until fully closed.
Disconnecting the instrument
• Rotate the plug locking ring-nut anticlockwise and remove it.
• Cover the socket with the cover provided.
WARNING: always ensure that the socket is closed with the cover provided when the
instrument is disconnected.
CONNECTING THE CONTROL PANEL TO THE SOCKET
HRC 1006 - HRC 1008 - HRC 1002 L - HRC 1004 L - HRC 1006 L - HRC 1008 L
Connecting the instrument
After installing the socket as described above, proceed as follows:
• Rotate the ring-nut of the protective cover anticlockwise and remove it.
• Insert the instrument plug into the relevant socket, taking care that the position of insertion is
correct.
• Turn the plug locking ring-nut clockwise until fully closed.
Disconnecting the instrument
• Turn the plug locking ring-nut anticlockwise until fully open and remove.
• Cover the socket with the cover provided, turning the ring-nut clockwise.
WARNING: always ensure that the socket is closed with the cover provided when the
instrument is disconnected.