Troubleshooting
A qualified technician must carry out repairs if required.
Fault
The appliance is not
working
The dispenser is not
cooling
Tap leaks
Product leaks from the
back of the bowl
Loud noises
Tap does not distribute Ice blocked inside the bowl
Slush has stains
Technical Specifications
Note: Due to our continuing program of research and development, the specifications herein may be
subject to change without notice.
Model
Voltage
UA044
220-240V~
50Hz
UA045
UA046
Dimensions
Model
H x W x D mm
UA044
940 x 280 x 610
UA045
940 x 496 x 610
UA046
940 x 714 x 610
UA044_UA045_UA046_ML_A5_v1_20240112.indb 13
UA044_UA045_UA046_ML_A5_v1_20240112.indb 13
Probable Cause
The unit is not switched on
Plug or lead is damaged
Fuse in the plug has blown
Mains power supply fault
Coolant leak
Fan motor failed
Airflow obstructed to the
condenser
Tap piston not lubricated well
Tap piston is defective
Bowl not fitted correctly
Bowl seal not lubricated well
Bowl seal is defective
Front seal is not applied correctly
Seal not lubricated well
Auger seal is dirty
Auger seal is worn
Power
Current
(W)
(A)
435W
2.23A
765W
3.5A
1040W
4.9A
Net Weight
(kg)
35
57
78
Solution
Check unit plugged in correctly and
switched on
Replace Plug or lead
Replace the fuse
Check mains power supply
Call POLAR agent or qualified technician
Call POLAR agent or qualified technician
Increase the gap between appliance and
obstacles/heat source
Lubricate the tap piston
Replace the Tap piston
Check the positioning of the bowl
Lubricate the bowl seal
Replace the Bowl seal
Put the seal correctly
Lubricate the seal
Turn off the unit to let ice melt
Clean the auger seal
Replace with a new one
Capacity
Bowls
(litres)
1
12
2
24
3
36
Noise level
<60 dB
EN
Refrigerant
R290
R290
R290
13
2024/1/12 10:10
2024/1/12 10:10