ENGLISH - TRANSLATION OF THE ORIGINAL INSTRUCTIONS
concentrate the air flow.
1. Insert the plug of the power cord
(1) into the power socket.
2. If
necessary,
concentrator nozzle.
3. Select the desired motor speed via
switch (2) and the corresponding
working temperature on switch (3).
4. If the temperature switch (3) is set
to "0", the unit will not emit hot air.
5. After use, set the switches to '0'
and disconnect the appliance
from the power socket.
6. Allow it to cool down before
storing the appliance.
CLEANING AND GENERAL
MAINTENANCE
Before cleaning, disconnect the
plug from the electric socket. Use a
Problem
The appliance never
emits hot air.
The cord or appliance
emits abnormal noises
or sparks.
The appliance starts
to emit cold air during
use.
The air flow has
decreased.
If the problem is not solved, contact your dealer or Labor Pro Technical Service
Centre.
install
the
TROUBLESHOOTING
Possible reason
Fault in the heating
element.
The appliance or
the power cord is
damaged.
The cold air button
was pressed.
The overheating
protection is
activated.
The rear grille is
obstructed.
dry or slightly moistened cloth.
CLEANING THE MOTOR GRILLE
Unscrew the ring nut (6) and clean
the motor grille with a soft brush or
toothbrush. You can use a cloth
dampened with alcohol.
Refit the ring nut and the motor
grille, taking care to position them
correctly.
To ensure optimum performance of
the appliance, regular cleaning of
the filter is recommended (daily for
heavy use or once a week).
TECHNICAL SUPPORT
For repairs or to purchase spare
parts, contact your dealer. If this
is not possible, contact the Labor
Pro Assistence Centre by email at:
assistenza@laborprosrl.com
Request inspection or
repair at the place of
Release the cold air
Clean the motor grille.
EN
Action
purchase.
button.
9