DRAIN CONNECTION
• Connect the tube (6) supplied, at the connection (7) and
the other end to a drain, previously prepared.
IMPORTANT: The drain siphon must be
positioned below the support surface of the
machine by at least 20 cm.
LOAD CONNECTION
• Connect the hose (8), supplied, to the fitting (9)
positioned at the bottom rear of the machine.
• Connect the other end of the tube (8) to a softener.
IMPORTANTE:
the machine to a mains water supply with
drinking water suitably sweetened with a
maximum hardness of 3.5 / 5 ° French (60/85
ppm).
Check that the supply pressure does not
exceed 4 bar (0.4 MPa). f the pressure is
higher, install a pressure reducer.
IMPORTANTE:
must be positioned a tap of capacity to
separate the network system plant from the
plant of the machine.
Manuale_DomobarSuperHXManuale_Rev0_03-2016_5lingue.indd 17
All manuals and user guides at all-guides.com
It is mandatory to connect
Upstream of the machine
A
R
7
6
8
9
17
25/03/16 14:34