TROUBLESHOOTmNG
Probmem
No AC output
is avaimaMe, but
generator
is running.
Cause
i.
One
of the circuitbreakers is
open.
2.
Fauit in generator.
3.
Poor connection or defective cord
set.
4.
Connected
device
is bad.
Correction
[.
Reset circuit
breaker.
2.
ContactAuthorized
service fadiity.
3.
Check and repair.
4.
Connect
another
device
that is in
good
condition.
Generator
runs
good
at no-toad
1.
Short
circuit
in a connected
load.
1.
Disconnect
shorted
electrical
load.
but
"bogs"
down"
when
toads
are
2.
Generator
is overloaded.
2.
See "Don't
Overload
Generator".
connected.
3.
Shorted
generator
circuit.
3.
Contact
Authorized
service
fadiity.
I.
Failed battery.
I.
Replace
battery.
Generator
will
not
start;
or
starts
and
runs
rough.
2.
Low oil level.
2.
Fiil crankcase
to proper
level or
place generator
on level surface.
Generator
shuts
down
during
Out
of gasoline.
Fiil fuel tank.
operation.
Generator
lacks
power.
Load is too
high.
See "Don't
Overload
Generator".