Operating data
Gear
Release Torque/Safety Clutch
Core bit Ø concrete (DK12/13/14)
Core bit Ø concrete (DK16/17/18)
Core bit Ø concrete (DK08/09)
Water volume DK08/09/12/13/14/16/17/18 approx. l/min
Water volume DK11 approx.
Water volume DK119 approx.
3.2
List of contents
DK11
-
Diamond core drill (1), with water supply (1a), handle with clamp ring (1c), PRCD
inline protector (1d), carrying case and instructions manual.
Special accessories: start drilling aid with water collecting ring WR 10.
DK08/12/16
-
Diamond core drill (1), with ball valve and connect-nipple (1a), handle with clamp ring
(1c), PRCD inline protector (1d), carrying case and instructions manual.
Special accessories: Start drilling aid with water-collecting ring.
DK09/13/17
-
Diamond core drill (1), with ball valve and connect-nipple (1a), tail end (1b), handle
with clamp ring (1c), PRCD inline protector (1d), carrying case and instructions
manual.
Special accessories: Elastic bore piercer, start drilling aid with water collecting ring.
DK14/18
-
Diamond core drill (1), with ball valve and connect-nipple (1a), PRCD inline protector
(1d) and instructions manual.
DK116/
-
Diamond core drill (1) with adapter for dust exhausting, carrying case and instructions
DK118
manual.
DK119
-
Diamond core drill (1) with ball valve and connect-nipple (1a), PRCD inline protector
(1d), carrying case and instructions manual.
3.3
Sound emission and vibration acceleration (EN 50144)
The typical A-weighted sound pressure level is 86 dB(A).
The typical A-weighted sound capacity level is 99 dB.
The typical weighted acceleration is <2,5 m/s .
4.
P R E P A R A T I O N
Make sure that the machine did not get damaged by the transport. Check that the rated voltage indicated
on rating plate conforms with main voltage.
4.1
Connection to the power supply
According to the general safety precautions the electric connection of diamond core drills with water
supply is on principle to be done by a ground fault current interrupter (GFCI).
Likewise, those machines are only to be used at sockets with protective plug reception, earthed
according to the regulations.
According to those regulations WEKA core drills with water supply are provided with a PRCD inline
protector assembled between the cord.
The PRCD includes a ground fault current interrupter as well as an undervoltage breaker.
The PRCD is ready for service after connecting the electric main by pressing the ON button. If the
voltage is disconnected, the PRCD switches off and is, after the voltage returns, to start once more.
ATTENTION: Do not put the PRCD into water. It is regularly to be checked on perfect
functioning by pressing the TEST-key. Never use a core drill without a GFCI being directly
connected to the mains connection.
1/min 1
Nm
58
65 - 130
mm
70 - 140
80 - 150
0,8 - 1,1
l/min
0,3 - 0,5
l/min
1 - 1,5
2
12
2
3
25
12
30 - 55
15 - 25
32 - 65
15 - 30
25 - 60
0,5 - 0,8
0,4 - 0,6