GENERAL MAINTENANCE
Avoid using solvents when cleaning plastic parts. Most
plastics are susceptible to damage from various types of
commercial solvents and may be damaged by their use. Use
clean cloths to remove dirt, dust, oil, grease, etc.
PROBLEM
Workpiece contact does not depress
fully - tool does not operate
Tool operates properly, but nails do not
drive fully
Tool operates properly, but nails are
driven too deep
Tool jams frequently
Tool stops and LED flashes rapidly
Tool has charged battery and LED is
slowly flashing or LED does not turn
off after approximately ten seconds of
non-use
Tool will not drive a fastener or cycles
without driving a fastener
AFTER FRENCH AND SPANISH LANGUAGE SECTIONS.
MAINTENANCE
TROUBLESHOOTING
POSSIBLE CAUSE
Low nails
Work-contacting element is jammed
Air pressure is too low
Depth of drive isn't deep enough
Nail is too long for wood hardness
Trigger released too soon
Air pressure is too high
Depth of drive is too deep
Incorrect nails
Damaged nails
Loose magazine
Dirty magazine
Battery is low or has no charge
Trigger released too early
Tool has malfunctioned
Driving mechanism is dirty
NOTE: ILLUSTRATIONS START ON PAGE 12
CLEANING THE NAIL CHANNEL
See Figure 13, page 13.
If the tool will not drive a nail, or cycles without driving a nail,
glue residue from the nail strip may need to be cleaned from
the area around the driving mechanism.
 Remove the battery pack.
 Remove nails from the tool.
 Open the jam release latch and the magazine.
 Use a small amount of air tool oil on a clean cloth or cotton
swab to wipe down the nail channel, removing all traces
of glue.
 Reinstall nails in the tool and close the magazine.
11 — English
SOLUTION
Remove battery and replenish nails
Remove battery and clear jam
Increase power
Adjust depth of drive
Use nail length that is appropriate for
wood
Hold trigger until fastener is driven
Decrease drive power
Adjust depth of drive
Verify that nails are the correct size
Replace nails
Tighten screws
Clean magazine
Recharge battery
Remove battery and reinstall.
Take tool to nearest authorized repair
center
Clean the nail channel as described in
the Maintenance section of the manual