Cleaning, Care & Maintenance
Always turn off the Mixer and disconnect from the power supply before cleaning
Use warm soapy water to clean the Bowl, and mixing attachments. Do not use abrasive cleaning
chemicals as these can leave harmful residues
Clean the exterior of the appliance with a damp cloth
Dry all parts thoroughly after cleaning
Do not use jet/pressure washers to clean the appliance
Clean the appliance regularly
Trouble Shooting
Fault
The machine does not start
The hook doesn't constantly
turn
Technical Specifications
Code
Voltage
CD281
230V 50hz
4
43744 - CD281 Spiral Mixer.2.indd 4
Probable Cause
Lack of energy in the power
supply
The emergency stop button is
locked
The safety guard and/or the
head are up
The knob of the main switch is
in position "0"
The timer is in position "0"
The chain is loose
Power
Current
Watts
Amps
W x D x H (
750w
6A
720x 400x 620mm
Action Required
The timer is in position "0"
Rotate the button following the
direction of the arrow.
Correctly close both the safety guard
and the head.
Rotate the knob to position 1
Rotate the knob of the timer from 1 to
30 minutese
Call BUFFALO Agent or qualified
engineer
Dimensions
Weight Kgs
mm)
87kg
Bowl
Volume
22l