Descargar Imprimir esta página

Hayward AquaRite HC Low Salinity Manual Del Usuario página 18

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 25
Quantity of stabilizer (CYANURIC ACID in kg) required for 25 ppm
Volume of water in the pool in m³
Current salt
concentra-
tion (ppm)
30
37.5
45
52.5
60
67.5
0 ppm
0.75
0.94
1.13
1.34
1.53
1.69
10 ppm
0.45
0.56
0.68
0.81
0.92
1.01
20 ppm
0.15
0.19
0.23
0.27
0.31
0.34
25 ppm
0
0
0
0
0
0
Chemical water balance
BEFORE
The water must be balanced manually
the device is started up.
The following table summarizes the concentrations recommended by Hayward. Your water should be checked regularly to maintain
these concentrations and minimize surface corrosion or deterioration.
CHEMISTRY
Salt
1.5 g/l
Free chlorine
0.5 to 2.5 ppm
pH
7.2 to 7.6
20 to 30 ppm max.
Cyanuric acid
(Add stabilizer only if necessary)
(Stabilizer)
0 ppm in indoor pool
Total alkalinity
80 to 120 ppm
Water hardness
200 to 300 ppm
Metals
0 ppm
Langelier index
-0.2 to 0.2 (preferably 0)
AquaRite
HC LS
®
Only use spare parts supplied by Hayward brands
75
82.5
90
97.5
105
112.5
120
127.5
135
1.91
2.09
2.28
2.47
2.66
2.84
3.03
3.22
3.41
1.14
1.26
1.37
1.48
1.59
1.71
1.82
1.93
2.04
0.38
0.42
0.46
0.49
0.53
0.57
0.61
0.64
0.68
0
0
0
0
0
0
0
0
0
RECOMMENDED CONCENTRATIONS
Page 10 on 22
®
The device is designed to be connected to a protected outlet at all times. The AquaRite
unless the pool equipment is undergoing maintenance or the pool is to be closed (wintering).
142.5
150
If the water parameters are within the recommended ranges, the device can be started up.
3.59
3.75
2.16
2.25
0.72
0.75
0
0
5a. View and description of the home screen
Filtration stopped or insufficient flow
Maximum injection time reached
Filtration stopped or insufficient flow
Updated free chlorine measurement
Filtration stopped or insufficient flow
Free chlorine sensor flow error
5b. Commissioning of the device
5. OPERATION
Available relays
Time
On/Off button
Hydrolysis - Intensity in %
Flow
Max. pH set point (Acid)
7.2
Peristaltic pump operation
on/off
AL3
FL1
Electrolysis operation
on/off
0.00
Free chlorine setpoint
1.00
FL1
FL2
Menu access
Choose your preferred language
Confirm the current time and
and confirm using the OK
date using the OK button.
button.
AquaRite
HC LS
Page 11 on 22
®
Only use spare parts supplied by Hayward brands
HC LS must not be disconnected
®
Polarity 1
Polarity 2
Pol 1
Pol 2
Production automatically reduced
Cover
to % selected (20% by default)
Wait time
---
Insufficient salt / cell scaled up or to be replaced /
LOW
water temperature too low
Operation
on/off
Maximum setpoint of ORP
700
Filtration stopped or insufficient flow
FL1
Updated conductivity measurement
3000
Maximum conductivity setpoint
5000
Filtration stopped or insufficient flow
FL1
Lighting status and programme
Filtration status and programme
®

Publicidad