Descargar Imprimir esta página

Dornbracht 33 537 625 Serie Instrucciones De Montaje página 17

Publicidad

Operating conditions
US
Recommended flow temperature
Maximum short-term flow
temperature
Minimum flow pressure
Maximum flow pressure
Recommended operating pressure
Test pressure
Noise class I according to DIN 4109
In order for the noise levels to comply with
the national requirements, a pressure reducer
must be installed in the supply line at a static
pressure above 5 bar.
If combined with continuous flow heaters,
please take into consideration the max. pres-
sure difference indicated (30% cold-hot) and
the minimum flow volume (safety shutoff).
Please note the manufacturer's information for
the continuous flow heater.
Driftsvillkor
SE
≤ 149 °F
Rekommenderad inloppstemperatur ≤ 65 °C
Max. inloppstemperatur under
≤ 194 °F
korttid
15 psi
Minsta vätsketryck
73 psi
Max. vätsketryck
44 psi
Rekommenderat arbetstryck
232 psi
Provningstryck
Bullerklass I enligt DIN 4109
För att bullernivån inte ska överskrida gällande
gränsvärden enligt nationella föreskrifter, ska
en trycksänkare monteras in i försörjnings-
ledningen vid vilotryck över 5 bar.
Vid kombination med genomströmnings-
värmare måste hänsyn tas till den angivna
max. tryck differensen (30 % kallt-varmt)
och den minsta genomströmningsmängden
(säkerhetsavstängning).
Följ anvisningarna från tillverkaren av genom-
strömningsvärmaren.
≤ 90 °C
1 bar
5 bar
3 bar
16 bar
17

Publicidad

loading