1. Remove the sealing cap (4) from the air inlet (5).
2. Mount the air nipple to the air inlet (5).
3. Put a few drops of air device oil into the device via the air inlet.
4. Make sure that the trigger lever (3) is in the non-depressed position.
5. Connect the device to the compressed air source hose.
6. Start the device by pushing the trigger lever (4) down.
LOOSENING
1. Connect ratchet to air source.
2. Fit suitable socket onto the output square drive.
3. Adjust switch (1) on ratchet head to desired rotational direction (for most screws = counter
clockwise).
4. Place ratchet with socket onto the screw and start loosening the connection by twisting the
ratchet counter clockwise MANUALLY! As soon as the screw has been loosened a bit, you can
push down the trigger lever (3) and drive the screw out with air pressure support.
TIGHTENING
1. Connect ratchet with air pressure system
2. Fit suitable socket onto the square drive (2).
3. Adjust the switch (1) to desired rotational direction (for most screws = clockwise).
4. Put in the screw by hand and screw it in 2 or 3 turns manually.
5. Put ratchet with socket onto the screw and push down the trigger lever (3) to screw in the screw
with air pressure support. CAUTION: Wear safety gloves and hold the ratchet firmly. The ratchet
will build up a strong torque against its rotational direction as soon as the screw has reached its
dead stop. Risk of injury caused by negligence.
CAUTION: Check all screw connections after tightening with a torque wrench for the prescribed
torque.
TROUBLESHOOTING
Probable Cause
Dirty or clogged air passages
Insufficient air supply
Air leakage
Worn/damaged wear & tear parts
Tool matching
ENVIRONMENTAL PROTECTION
Dispose of this product at the end of its working life environmentally.
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories
and packaging should be sorted, taken to a recycling centre and disposed of in a manner
which is compatible with the environment. Contact your local solid waste authority for
recycling information.
BGS technic KG
Bandwirkerstr. 3
D-42929 Wermelskirchen
(Insufficient power)
Flush and lubricate tool, drain air tank and supply line
Increase line pressure, make sure compressor matches
tool's air pressure and consumption needs
Use teflon tape at all fittings and joints.
Check tool for worn or damaged o-rings & seals.
Replace as necessary
Be sure you are using a tool suited for the requirements of
the job at hand.
Tel.: 02196 720480
Fax.: 02196 7204820
mail@bgs-technic.de
Solution
www.bgstechnic.com
© BGS technic KG, Copying and further use not allowed