ELECTRICAL CONNECTION
• The installation of this appliance and the connection to the electrical network should be
entrusted only to an electrician perfectly to the fact of the normative regulations and which
respects them scrupulously.
• Protection against the parts under tension must be ensured after the building-in.
• The data of connection necessary are on the stickers place on the hob casing near the
connection box.
• The connection to the main must be made using an earthed plug or via an omnipolar
circuit breaking device with a contact opening of at least 3 mm.
• The electrical circuit must be separated from the network by adapted devices, for example:
circuit breakers, fuses or contactors.
• If the appliance is not fitted with an accessible plug, disconnecting means must be
incorporated in the fixed installation, in accordance with the installation regulations.
• The inlet hose must be positioned so that it does not touch any of the hot parts of the hob
or oven.
Caution!
This appliance must only be connected to a network 220-240 V~ 50/60 Hz.
Always connect the earth wire.
Respect the connection diagram.
The connection box is located underneath at the back of the hob casing. To open the cover use a
medium screwdriver. Place it in the slits and open the cover.
Mains
220-240V~
50/60Hz
400V~ 50/60Hz
220-240V~
50/60Hz
* calculated with the simultaneous factor following the standard EN 60 335-2-6
Connection of the hob
For the various kinds of connection, use the brass bridges which are in the box next the terminal
Monophase 220-240V~1P+N
st
Put the 1
bridge between terminal L1 and L2,the 2
N2.
Attach the earth to the terminal "earth", the neutral N to terminal N1 or N2, the Phase L to one of
the terminals L1, L2 or L3.
Biphase 400V~2P+N
Put a bridge between terminal L1 and L2 and between N1 and N2.
Attach the earth to the terminal "earth", the neutral N to terminal N1 or N2, the Phase L1 to the
terminals L1 and the Phase L2 to the terminal L3.
Connection
Cable diameter
1 Phase + N
3 x 2.5 mm²
2 Phases + N
4 x 2.5 mm²
3 Phases
4 x 2.5 mm²
Cable
H 05 VV - F
H 05 RR - F
H 05 VV - F
H 05 RR - F
H 05 VV - F
H 05 RR - F
nd
between L2 and L3, the 3
142
EN
Protection calibre
25 A *
16 A *
16 A *
th
between N1 and

Publicidad