The device is designed to be connected to a protected outlet at all times. The ProChem Double must not be disconnected
unless the pool equipment is undergoing maintenance or the pool is to be closed (wintering).
Assuming that the chemical balance of the water is within the recommended ranges, the device can be started up.
6a. Description of the home screen and defaults parameters
Default parameters
n
Item
1
Language
2
Set Point value
3
Dosing method
4
OFA Time
5
Calibration
6
Flow Input
(Reed Sensor)
7
Circulation pump
8
Dosing type
9
Power ON Delay
10 Flow Delay
Init. Default. Menu
Press
+
and switch on the device.
Set reset routine;
Init. Default: restore default parameters device only
Init. WiFi Module: restore default parameters WiFi module only
Init. Calib. HW: restore raw HW calibration parameters.
Note: please make the probes calibration before using the system
6. SETUP AND OPERATION
Value
EN
7.4 pH
700 mV
Acid (pH)
Low (ORP)
OFF
Full
NO (normally open)
(pH & ORP only)
ON (Enable)
PROP; Relay Aux1, Aux2, Aux3 are disabled
OFF
OFF
ProChem Double | pH · ORP · Chlorine
Only use spare parts supplied by Hayward brands ®
Display
1.2 ppm
Low (Chlorine)
NC (normally closed)
(Chlorine)
Button to decrease the value
Escape button
Enter button
Button to increase the value
Measure alarm ranges default parameters
n
Item
1
Temp. Measure min
2
Temp. Measure Max
3
pH Measure
4
pH Measure
Max
5
ORP Measure min
6
ORP Measure Max
7
Cl Measure min
8
Cl Measure Max
Init. Default
■ Init. Default
□ Init. WiFi Module
□ Init. Calib. HW
Page 13 on 42
Limits
+ 10°C
+ 38°C
min
6 pH
8.0 pH
+450 mV
+850 mV
0.5 ppm
2 ppm