"Air unit" installation M093A
- Drill a 50mm hole on the wall.
- (A) Place the 'air unit' in the hole, inserting the IR sensor wire in advance.
- (B) Firmly hold the 'air unit' to ensure a correct placement, insert the washer (4), take
the wire passes through the washer hole and firmly screw the 3 M6 nuts (5).
- (C) Move the bezel to completely hide the hole.
- (D) Place the 3 spacers (6) on the threaded bolts. Connect the grounding wire to the
earth tag (7), make sure the grounding connection is safe and reliable. Place the round
metal plate (8) as shown on the picture.
- (E) Place the round metal plate (8) through the threaded bolts, firmly fasten the
straight connector with its nut (9), and firmly fasten the round metal plate (8) with the 3
M6 nuts (5). Finally push & lock the corrugated tube to the straight connector (9).
WARNING: missing of this sequence may impair grounding connection and safety of
the product.
Check the installation so that the IR sensor cables or the ground are not visible,
the corrugated tube must completely protect them.
"Motor unit" installation M092A & M093A
- Carefully remove the casing since it is connected to the base by a tab that joins the
two pieces (casing and base) at the rear. Remove the casing keeping it at an angle at
all times (Figure 3) until the upper tab is completely withdrawn, taking care to not
damage the internal components, in particular the electronic circuit, and not damage
the surface of the casing.
- (A) Make four drill holes with an 8 mm (0,31") diameter in the wall, using the provided
template.
11