Descargar Imprimir esta página

Gaggenau AR 413 722 Instrucciones De Instalación página 8

Módulo del ventilador

Publicidad

Idiomas disponibles

Idiomas disponibles

Preparing kitchen units
The stability of the fitted unit must also be guaranteed
after the cut-out work.
Make the cut-out in the bottom plate in accordance with
the installation drawing.
After the cut-out work is complete, remove the shavings.
Notes
Provide space for the filter unit AA 413 722.
Measurements and installation options see
installation instructions AA 413 722.
The position of the cut-out can be varied according
to the local conditions.
The distance between the feet must be at least
23
5
/
" (600 mm).
8
The base panel must be removable or an opening of
at least 23
/
" x 4" (600 x 100 mm) must be
5
8
provided so that the filter can be changed.
8
Note: For a base height of less than 5" (130 mm), an
opening towards the front must be created. This part of
the bottom plate can be reinserted after installation.
Exhaust opening in the base panel
Provide an air outlet in the base panel, minimum cross-
section approx. 120 square inches (720 cm²). Make the
exhaust opening in the base panel as large as possible
in order to keep drafts and noise to a minimum.

Publicidad

loading