Understanding Charge LEDs.
LED
25%
Red LED
50%
Red LED
75%
Orange LED
100%
Green LED
Maintenance
Green LED
Understanding Error LEDs.
Error Conditions will be indicated by the following LEDs.
LED
Reason/Solution
Charger is in Standby mode or Battery voltage is too low for charger to detect.
Solid
Solid
Battery voltage is too high for the selected charge mode. Check the battery and charge mode.
Solid
Possible battery short / Battery will not hold a charge. Have battery checked by a professional.
Solid
Reverse polarity. Reverse the battery connections.
Charger internal temperature too high / Charger will resume function once the Charger internal temperature drops.
Flashing
Charger ambient temperature too cold / Charger will resume function once the Charger ambient temperature rises.
Explanation
The 25% Charge LED will slowly pulse "on" and "off", when the battery is less than 25% fully charged. When the battery is 25%
charged, the red Charge LED will be solid.
The 50% Charge LED will slowly pulse "on" and "off", when the battery is less than 50% fully charged. When the battery is 50%
charged, the red Charge LED will be solid.
The 75% Charge LED will slowly pulse "on" and "off", when the battery is less than 75% fully charged. When the battery is 75%
charged, the orange Charge LED will be solid.
Pulsing Green LED - Bulk charge complete, optimizing battery for extended life.
Solid Green LED - When the battery is 100% charged, the Charge LED will be solid green.
After the battery is fully charged, the charger will continue monitoring the battery, and provide ongoing maintenance and
optimization. The 100% Charge LED will pulse "on" and "off" slowly during these cycles. The charger can be left connected to the
battery indefinitely.