Descargar Imprimir esta página

bombas hasa FONTANA-10 Manual De Instrucciones página 5

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 1
In the next sections you will find all the useful indications to best adapt the pump to your needs and allows you
to do by your own little cleaning and maintenance that this kind of product requires. The letters you will find
between brackets correspond to the components mentioned in the final exploded drawing.
All types and models are subject to continuous improvement and the manufacturer therefore reserves the right
to make
modifications in the shape, equipment and technology.
2.1
Application limits.
Maximum water temperature: 35 [°C].
Minimum water temperature: 4 [°C].
Maximum depth of immersion: 1 [m].
3
Use and regulation.
Before being activated, the pump should be settled in the place where it will work.
For its correct working, the pump requires a minimum water height of 5/10 [cm], as shown in the picture (Fig.
1).
The pump may be connected either to flexible tubes ø 12X16 [mm] or to rigid ones ø 13 [mm].
The capacity may be changed using the flow control device (present in the lowest part of the pump),
depending on the necessities, as shown in the picture (Fig. 2).
Finally, the pump is equipped with an impeller lid provided with hosetail, in order to be used also if not
submersed. To reach the hosetail is sufficient to take off the filter holder opening.
Once the pump is installed, the plug must be easily accessible.
3.1
Fountain kit (¡Error! No se encuentra el origen de la referencia.).
The telescopic tube 1 can be connected to the pump with the flow device 2 or the adaptor piece 5.
The position of the spray head 4 is adjustable up or down using the telescopic tube. The spray height is also
adjustable by the rotation of the flow regulator 2. The bell/dome head diameter 3 can be adjusted by rotating
the top of the head. To clean all fountain parts flush with water.
3.2
Maintenance.
The maintenance of the pump is limited to the cleaning.
Before handling the pump, any electrical equipment must be disconnected and remember also never to put
hands in water when the pump is working.
Cleaning concerns essentially the foam filter, that must be cleaned regularly, and the rotor, that must be
cleaned in case the pump gets jammed.
To clean the foam filter, take off the filter holder opening and rinse the filter as shown in the pictures (Fig. 3).
Each 3 months, wash the other parts of the pump in tepid water.
As regards cleaning of the rotor, it is necessary to open the pump as shown in picture and to slip off the rotor
holding it by the impeller, if necessary helping yourself with tweezers.
Once taken out, the rotor must be cleaned in tepid water and the same operation must be done for the box
where the rotor lies.
4
Disposal notes.
EU directive 2002/96/EC classifies this product as an electrical or electronic tool. Do Not dispose
of this tool as unsorted municipal waste. Dispose of this tool at a collection or recycling centre
according to local and national law. The consumer has an important role in reducing the disposal
of waste by returning waste electronic/electrical tool for recycling. Recycling avoids the
dispersion of hazardous materials into the municipal waste stream. The crossed-out bin symbol
reminds the user not to dispose of this product as unsorted municipal waste.
The pump must never run without water.
Minimum depth of immersion: 5/10 [cm]
5

Publicidad

loading

Este manual también es adecuado para:

Fontana-20Fontana-30Fontana-40Fontana-50