Before proceeding make sure that:
• the mains voltage corresponds to the voltage on
the refrigerator 220V240V/50Hz/1Ph; to ensure
proper operation it is essential for the power
supply voltage to come within a range of +/- 10%
of the unit' s rated voltage
• the electric system to which the refrigerator
is sized to cater for the rated electric output
of the buffet unit being installed
• the electronic system to which the refrigerator is
connected is made in compliance with current
standard requirements
• the electric connections and the installation
of the thermomagnetic circuit breaker have
been done by qualified person.
Connecting steps :
• lnstall a thermomagnetic circuit breaker
suited to the rated output of the unit being
installed
• Connect the refrigerator unit to the
thermomagnetic circuit breaker outlet
• Check that the refrigerator is in order as
demonstrated by the pilot light incorporated
in the main switch coming on
9 - Maintenance instructions
The smooth operation and life of the
equipment are mainly determined by correct
and regular maintenance
Cleaning :
Regular cleaning of the refrigerator unit is
strongly recommended each month. Please
follow the instructions below.
Disconnect the refrigerator power supply
cable from the mains prior to carrying out any
type of cleaning operation.
Cleaning the refrigerator surface :
Clean the refrigerator with mild detergent
and warm water then dry it with a soft cloth.
Do not use abrasive detergents!
Cleaning the inside of the refrigerator :
Wipe clean with warm water and a mild
detergent solution and then wipe until dry.
Do not use abrasive detergents or strong
scented cleaning agents.
Cleaning the condenser :
For an efficient operation of the refrigerator it
is advisable to clean the condenser regularly
approx. every 4 months with a dry brush or
vacuum cleaner.
10 - Troubleshooting
Refrigerator stops working (light off):
• Power supply failure
Remedies :
Check that the plug is inserted properly in
the socket
• Check that the switch on/off
• Check that the mains voltage powers the
plug
Refrigerator temperature go up :
• Unit to near to a heat source
• Condenser dirty or close
Remedies :
• Move the counter or the heat source further
away
• Clean the condenser
11 - Technical service
For technical service please contact the dealer
technical department and give the serial Q, of
the unit and the date of purchase from the
supplier.