Quick installation guide
EN
3.4
Installations
If all necessary components are installed on the door (EAV4 or EAV4+ locking
system, frame parts, magnetic clip (optional for EAV4+), power supply unit)
3
and the operating voltage 24V DC is applied (start-up), can electrically unlo-
cked. Acoustic confirmation (beeps) only for EAV4+, not for EAV4 Standard.
There is no action when the door is open.
Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen
T +49 369 3950 - 0 ∙ www.winkhaus.com ∙ Subject to technical changes
blueMatic EAV4 / EAV4+
Warning! The installation of electrical equipment requires
expertise, thus such work should only be carried out by on
electrician. Generally assemble and install always only with the
power off!
Warning! IMPORTANT ADVICE!
To avoid blocking the locking mechanism, no key or key ring
must be inserted in the locking cylinder!
Notice: First the door has to close easily, then you can test
electrical performance!
Notice: After the door elements have been installed, an initial
functional check should be carried out on site in the presence of
the client or his representative and a visual / functional
acceptance report should be created.
The cables included in the scope of services should be laid at
this point in time to the intended transfer point (e.g. junction
box). They should be protected from damage and from other
trades (plaster, drywall, ...) for the subsequent construction
period.
Loose / bundled cables hanging freely should be avoided.
20