11.
Troubleshooting
Symptom
Display unit does not turn
on
Display turns on, but does
not show image.
Display shows an
unresponsive image
Battery does not hold a
charge
No Signal
Depth measurement shows: ROLOC PLUS is out of range
ROSCOPE 1000/i2000
Error Code 1
"unplugged"
ROSCOPE 1000/i2000
Error Code 2
"Digital / No Video Sync"
ROSCOPE 1000/i2000
Error Code 3
"Analog / No Video Sync"
ROSCOPE 1000/i2000
Error Code 4 (PPI)
"Video Data Not in Correct
Format"
ROSCOPE 1000/i2000
Error Code 5
"Aurora Detected"
22
Possible Reason
Battery is discharged
Verify battery is in the battery
compartment
Faulty electronics
Loose cable connection
Imager head covered by debris
Image processor encountered
an error
Battery may have discharged
slightly during storage
Run time dependent on LED
usage
Battery may be damaged
Life cycles of battery expired
Wrong frequency
Error present when imager has
been plugged in and working,
and then has been removed
Indicates that a digital imager has
been identified but no video sync
are present.
Indicates that an analog imager
has been identified but no video
syns are present.
Indicate that the video data is not
in the correct format.
This is a condition where the
imagers automatic correction
scheme (digital imager only)
results in an image with video
artifacts – the imager is then
reset. If this condition persists
after subsequent retries, this
error is then presented.
ENGLISH
Solution
Recharge battery
Place battery in the battery
compartment
Contact ROTHENBERGER
Service Center
Check cable connections.
Clean imager head
Turn OFF unit/turn ON to
reset processor
Remove battery when
storing
Recharge battery more often
when extensive use of LEDs
Replace battery
Replace battery
Verify frequency of your
sonde and adapt ROLOC
frequency via menu
Verify strongest signal
Contact Service Department
Contact Service Department
Contact Service Department
Contact Service Department
Contact Service Department