Cancel Connection (Door Contact, Optional) – Switch Control
Connect the switch to the CANCEL terminal. 2N LiftIP 2.0 is set to contact control from the
factory. Both the jumpers are mounted on the configuration jumper. The CANCEL input can
be set to N/C contact too. If the case is a N/C contact, invert the CANCEL input function in the
device web configuration.
Cancel Connection (Door Contact, Optional) – Voltage Control
DC voltage ranging from 5 to 48 V can be used. Slide both the jumpers off the configuration
jumper for voltage control. To use voltage disconnection control, invert the CANCEL function
in the device web configuration.
If voltage presence signals a closed door, make sure that the power supply is backed up against
power outage.
!
Keep the polarity in all the connection cases (see the cover print).
Device Configuration
2N LiftIP 2.0 is configured using a PC equipped with any Internet browser.
• Launch your Internet browser (Chrome, Firefox etc.).
• Enter the device IP address (http://192.168.1.100/, e.g.).
• Log in using the username Admin and password 2n.
You have to know the IP address of your device to log in to the integrated web server. By default,
2N LiftIP 2.0 is set to the dynamic IP address mode – it retrieves the IP address automatically
if there is a properly configured DHCP server in the LAN. If the DHCP server is unavailable,
2N LiftIP 2.0 can be operated in the static IP address mode.
In case the device is still unavailable (forgotten IP address, network configuration change etc.),
you can use the VOL−/RESET/CONFIG button on the left-hand upper side of main unit to make
an alarm network change.
Factory Reset
Follow the instructions below to reset the factory default values:
• Press and hold the RESET button.
• Wait until the red and green LEDs go on simultaneously and the acoustic signal can be heard
♪ (approx. 30 s).
• Wait until the red LED goes off and the acoustic signal can be heard ♪ ♪
(approx. for another 3 s).
• Wait until the green LED goes off and the red LED goes on again and the acoustic signal can
be heard ♪ ♪ ♪ (approx. for another 3 s).
• Wait until the red LED goes off and the acoustic signal can be heard ♪ ♪ ♪ ♪ (approx. for
another 3 s).
• Release the RESET button.
Refer to the 2N LiftIP 2.0 user manual at wiki.2n.com for device configuration details.
4