Installation and use
A. The connection
Note: When connecting and disconnecting the
handle, be sure to turn off the power to avoid
dam aging the control circuit board
1. Connect the handle device to the handle socket
of the host machine.
2. Heating core required by the device
3. Put the welding table well and put the handle
on the handle rack .
4. Connect the power supply.
5. Turn on the power switch and the display window
displays "---", at which time the welding table
is in standby state
Temperature up: pressing ▲once will increase
the set temperature by 1℃. The temperature
display will show the set temperature; if pressing
▲for at least one second, the set temperature
will rise rapidly until ▲is released when the target
temperature is reached.
Temperature down: pressing ▼once will decrease
the set temperature by 1℃. The temperature
display will show the set temperature; if pressing
▼for at least one second, the set temperature
will fall rapidly until ▼is released when the target
temperature is reached.
After the parameter value is set, in "Ch1", "CH2",
"CH3", Select the channel you want to set, press
and hold the "CH1" key to change The data is
stored in the "CH1" channel; in the same way,
press "CH2" or "CH3" Then save the data in CH2
or CH3 channel。
Take out:
When you need to Take out the memor y data,
just click (less than 1 second)"CH1", you can
Take out the saved data, and similarly press "CH2"
or "CH3" to recall the memorized data。
P09
Installation and use
C. Celsius and Fahrenheit
temperature conversion:
Twice press the "SET" key
in the power-on state to
switch Celsius or Fahrenheit.
The unit shows Celsius "℃"
Fahrenheit "
"
D. When the host is off, press
and hold the "CH1" key,
Then turn on the power to
turn off or enable the key
lock Enable display: "
Close to display: "
E. F Press and hold "CH1"
in the boot state to turn
off or enable the buzzer.
When enabled, "
" is
displayed and a prompt is
sounded. Turn off show
the "
"
F. When the host is off, press
and hold the "CH3" key and
turn on the power to enter
the standby temperature
setting interface.
Standby temperature are:
0℃/150℃/180℃/200℃
(set to 0℃, the standby
temperature will be turned
off ) After the setting is
completed, short press CH3
to save and exit. (This function
can only be used when using
C-245 heating element)
G. Calibration temperature:
Every time the heating element
is replaced, the temperature
"
"
P10