Routine Maintenance
1.When servicing or repairing this machine, turn off the power or unplug it for safety;
2.Wipe the surface of the hand dryer with a wrung soft cotton cloth or towel. Never rinse the hand dryer
directly with water;
3.Please use neutral detergent to clean the hand dryer. It is forbidden to use decontamination powder,
abrasive powder and oil, acid and alkaline cleaners to clean the surface of the hand dryer;
4.Do not put screwdrivers or any slender sharp objects into the air outlet, otherwise it may cause
damage to internal parts and accidents such as electric shock;
5.Please keep the surface of the transparent cover of the sensor free of scratches, and do not clean
the surface with steel wool, sandpaper or any rough objects, otherwise it will reduce the sensitivity of
the sensor;
6.To ensure the safety of use, it is prohibited to use it for other purposes except to dry hands;
7.To prevent damage to parts or personal injury, be sure to avoid direct contact of water with live parts,
and do not hit the housing;
8.For indoor installation and use only.
Filter Cleaning
POWER
CHECK
Remove the filter f-
Pinch the middle pr-
rom the filter box.
otruding part and pull
down to remove the
filter box.
EN
Gently dust or blow off the
It can be rinsed with
dust on the filter. If the filter
water, and dried for
screen is too dusty or used
use after cleaning.
for more than 3 years, it
needs to be replaced.
3
Troubleshooting
Trouble
Check the power switch
The hand dryer does not work
Induction device wire loose
Induction device failure
The motor is damaged/There are
The motor does not work
other objects in the wind wheel
Damaged heating element
No warm air
Whether the room temperature
exceeds 25°C
Note: This product needs to be repaired by professionals of our company. Repairing the machine
without any technical assistance may cause damage to parts or personal injury.
Product Introduction
Shell
Power indicator
POWE R
CHEC K
Running indicator
The filter
The filter box
Air outlet
Induction device
EN
Analyze
Solutions
Turn on the power
Connect the wires
Notify after-sales
maintenance
When the ambient
temperature exceeds
25°C, the heating will
automatically turn off
POWER
CHECK
Induction device
Power switch
Heating switch
Motor cover
Circuit control board
Motor base
Power cable
4