1) After configuring the parameters marked with
work according to the new parameter values.
2) Can be used to set the length limit of the displayed data on the screen. When the baud rate is set to
115200, the value displayed on the LCD is 1152.
3) For the parameters marked with
"Protection". Otherwise, the parameter settings will not succeed.
Protection
Input voltage protection:
1.
The following rules must be followed when modifying the battery's input voltage parameters:
Over-voltage limiting voltage (16.2/32.2/64.4V) ≥ Over-voltage disconnect voltage ≥
Over-voltage reconnect voltage +1V.
Over-voltage reconnect voltage ≥ Low-voltage reconnect voltage.
Low-voltage reconnect voltage ≥ Low-voltage disconnect voltage +1V.
Low-voltage disconnect voltage ≥ Low-voltage limiting voltage (10.5/21/42V).
Over voltage
12V: 16V
disconnect
24V: 32V
3)
voltage
48V: 64V
3)
: please set them following the input voltage rules in the chapter
12V: 12.5V~16.2V; step size 0.1V
24V: 23V-32.2V; step size 0.1V
48V: 44V-64.4V; step size 0.1V
1)
, the inverter will restart automatically. It will resume