CARE AND MAINTENANCE
WARNING: Disconnect power supply before servicing. See SAFETY INFORMATION before proceeding.
Routine maintenance should be done at least once a year.
•
W
ipe grille with a dry cloth.
• Remove excess dirt and dust from the fan housing with a vacuum cleaner.
• Do not use solvents, thinner or harsh chemicals for cleaning the fan.
• Do not allow water to enter the motor.
• Do not immerse resin parts in water over 140º F.
TROUBLESHOOTING
PROBLEM
The fan seems louder
than it should
The fan is not
clearing the room
LIMITED 3 -YEAR WARRANTY
manufacturer will replace it free of charge, postage-paid at their option. This warranty does not cover products that have
been abused, altered, damaged, misused, cut or worn. This warranty does not cover use in commercial applications. Use
only manufacturer-supplied genuine warranty repair replacement parts to repair this fan. Use of non-genuine repair parts
will void your warranty. The manufacturer DISCLAIMS all other implied or express warranties including all warranties of
have other rights that vary from state to state.
This warranty is limited to the replacement of defective parts only. Labor charges and/or damage incurred during installation,
repair, replacement as well as incidental and consequential damages connected with the above are excluded. Any damage
to this product as a result of neglect, misuse, accident, imporper installation or use other than the purpose SHALL VOID
THIS WARRANTY.
Shipping costs for return product as part of a claim on the warranty must be paid for by the customer.
Inquiries regarding warranty claims can be directed to +1 (888) 828 2025, 8 a.m. - 6 p.m., EST , Monday Thursday,
8 a.m. - 5 p.m., EST, Friday.
POSSIBLE CAUSE
CFM too great
Damper not working properly or damaged
Bend in duct too close to fan discharge
Fan housing not securely attached
CORRECTIVE ACTION
Be sure the CFM rating on the fan matches
the size of your room
Check damper to ensure it is opening and
closing properly. If the damper has become
damaged, please call Customer Service
Be sure you do not have any sharp bends in
duct closer than 18 in. to the fan discharge
Use recommended size ducting to reduce fan
noise
Be sure the fan is securely attached
to your ceiling joists
Be sure a door or window is slightly ajar or
draw air out of the room without enough
Be sure the CFM rating on the fan matches the
requirements for your room size
NOTE: Using a tissue is not an accurate
method for determining if the fan is operating
properly. If the fan clears steam from the room
within approximately 15 minutes of completing
your shower, then the fan is operating properly.
11
ONE
Printed in China