9.
System/equipment faults
Warning
Code
Fault
W23
No electrode
power for more
than 20 minutes.
W24
Excessive electrode
power in relation to
the current steam
output.
W25
Max. admissible
electrode power
exceeded.
---
---
Error
Code
Fault
E23
No electrode
power for more
than 4 hours.
E24
Excessive electrode
power in relation to
the current steam
output.
E25
Max. admissible
electrode power
exceeded.
E26
Main contactor
sticks.
Equipment faults
Cause
Cause
Phase failure of heating voltage.
Obstructed water supply/shut-off valve
closed/insufficient water pressure.
Blocked or defective inlet valve.
Excessive back pressure in the steam line
(excessive channel pressure, steam line too
long or steam line bent), resulting in a loss of
water pressure via the water cup.
Leakage in the water system.
Required humidity has fallen too quickly.
Outlet valve defective, check/replace outlet
valve.
Obstructed flow in the steam cylinder.
Conductivity for cylinder type too high.
Outlet valve defective.
Obstructed flow in the steam cylinder.
Conductivity for cylinder type too high.
The main contactor is blocked in the active
position.
Remedy
Remedy
Check/switch on the service switch in the
power supply line. Check/replace fuses in
the power supply line.
Check water supply (filter, lines, etc.),
check/open shut-off valve, check water
pressure.
Check mesh in inlet valve, clean if
necessary. Replace valve.
Check channel pressure, check steam
installation. If necessary, install the pressure
compensation kit (see options).
Check/seal water system.
Automatic adaptation of the operating point.
Clean/replace steam cylinder.
Select correct cylinder type.
Check/replace outlet valve.
Clean/replace steam cylinder.
Select correct cylinder type.
Check/replace main contactor.