2- TECHNICAL SPECIFICATIONS
2.1- Product Features
- Control of a single-phase pool pump from 0.5HP to 2HP.
- Typical power supply voltage: 220V.
- Overload detection (motor thermal circuit breaker).
- Dry operation detection.
- Low flow detection (clogged filter or partially closed valve).
- Chlorine generator relay output (230V).
- Lighting control relay output (230V).
- Temperature sensor input.
- Anti-freezing system, enabled by purchasing the NTC probe kit.
- Remote input.
- Connectivity with the BS POOL chlorinators through remote mode and EyPools application.
- Monitoring of pump consumption, being able to check the accumulative.
- Advanced functions and relay status visualization through an LCD screen.
2.2- Recommendations and Safety Warnings
- The installation of the equipment must always be done by qualified personnel.
- Disconnect the equipment from the power supply before performing any assembly or
maintenance operations.
- Ensure that the electrical installation has the mandatory protective elements (overload and
ground leakage circuit breakers) and that they are functioning correctly.
- The equipment box is water splash-proof. However, it is highly recommended not to install
the equipment outdoors or directly exposed to the sun.
- Installation in corrosive environments may reduce the life of the equipment. Make sure not
to leave uncovered containers with acids nearby.